    Fluke 355 and 353 True-rms 2000 A Clamp Meters Call Irfan 085282731888/ 081908101888

    Faeture:
    Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
    The large 58 mm ( 2.3 in) jaw capacity is suitable for large or multiple conductors
    CAT IV 600 V, CAT III 1000 V rating for added user protection
    In-rush current measurement captures ‘ power-on’ surge current with accuracy and repeatability
    High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool ( 355 only)
    Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. ( 355 only)
    Accurately measure frequency up to 1 kHz for optimum troubleshooting
    Quickly analyze readings using the MIN, MAX, and AVG functions
    A large backlit display allows for easy visibility in low-lit areas
    Use the display hold feature to capture readings even when the display cannot be viewed
    Use the low-pass filter to smooth out noisy loads and stabilize readings

    Electrical specifications
    Current measurement dc and ac 10 Hz to 100 Hz
    Range : 40 A Resolution: 10 mA
    Accuracy, A: 1.5 % rdg + 15 digits
    Trigger Level for Inrush: 0.50 A
    Trigger Level for Hz Filter OFF: 2.50 A
    Trigger Level for Hz Filter ON: 0.50 A
    Range : 400 A Resolution: 100 mA
    Accuracy, A: 1.5 % rdg + 5 digits
    Trigger Level for Inrush: 5.0 A
    Trigger Level for Hz Filter OFF: 2.5 A
    Trigger Level for Hz Filter ON: 2.5 A
    Range : 2000 A; 1400 ac rms Resolution: 1 A
    Accuracy, A: 1.5 % rdg + 5 digits
    Trigger Level for Inrush: 5 A
    Trigger Level for Hz Filter OFF: 8 A
    Trigger Level for Hz Filter ON: 8 A
    Crest Factor ( 50/ 60 Hz)
    Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
    Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
    Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
    Current measurement ac 100.1 Hz to 1 kHz
    Range : 40 A Resolution: 10 mA
    Accuracy > 10 A : 3.5 % rdg + 15 digits
    Trigger Level for Inrush: 0.50 A
    Trigger Level for Hz Filter OFF : 2.50 A
    Trigger Level for Hz Filter ON : 0.50 A
    Range : 400 A Resolution: 100 mA
    Accuracy > 10 A : 3.5 % rdg + 5 digits
    Trigger Level for Inrush: 5.0 A
    Trigger Level for Hz Filter OFF : 2.5 A
    Trigger Level for Hz Filter ON : 2.5 A
    Range : 2000 A; 1400 ac rms Resolution: 1 A
    Accuracy > 10 A : 3.5 % rdg + 5 digits
    Trigger Level for Inrush: 5 A
    Trigger Level for Hz Filter OFF : 8 A
    Trigger Level for Hz Filter ON : 8 A
    Voltage measurement ( 355 only) dc and ac 10 Hz to 100 Hz
    ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
    Range : 4 V Resolution: 1 mV
    Accuracy: 1 % rdg + 10 digits
    Trigger Level for Hz Filter OFF: 0.050 V
    Trigger Level for Hz Filter ON: 0.050 V
    Range : 40 V Resolution: 10 mV
    Accuracy: 1 % rdg + 5 digits
    Trigger Level for Hz Filter OFF: 0.25 V
    Trigger Level for Hz Filter ON: 0.25 V
    Range : 400 V Resolution: 100 mV
    Accuracy: 1 % rdg + 5 digits
    Trigger Level for Hz Filter OFF: 6 V
    Trigger Level for Hz Filter ON: 6 V
    Range : 600 V ac rms Resolution: 1 V
    Accuracy: 1 % rdg + 5 digits
    Trigger Level for Hz Filter OFF: 6 V
    Trigger Level for Hz Filter ON: 6 V
    Range : 1000 V dc Resolution: 1 V
    Accuracy: 1 % rdg + 5 digits
    Voltage measurement ( 355 only) ac 100.1 Hz to 1 kHz
    ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
    Range: 4 V Resolution: 1 mV
    Accuracy: 3 % rdg + 10 digits
    Trigger Level for Hz Filter OFF: 0.050 V
    Trigger Level for Hz Filter ON: 0.050 V
    Range: 40 V Resolution: 10 mV
    Accuracy: 3 % rdg + 5 digits
    Trigger Level for Hz Filter OFF: 0.25 V
    Trigger Level for Hz Filter ON: 0.25 V
    Range: 400 V Resolution: 100 mV
    Accuracy: 3 % rdg + 5 digits
    Trigger Level for Hz Filter OFF: 6 V
    Trigger Level for Hz Filter ON: 6 V
    Range: 600 V ac rms Resolution: 1 V
    Accuracy: 3 % rdg + 5 digits
    Trigger Level for Hz Filter OFF: 6 V
    Trigger Level for Hz Filter ON: 6 V
    Ohms measurement ( 355 only)
    Range: 400 & Resolution: 0.1 &
    Accuracy: 1.5 % + 5 digits
    Range: 4 k& Resolution: 1 &
    Accuracy: 1.5 % + 5 digits
    Range: 40 k& Resolution: 10 &
    Accuracy: 1.5 % + 5 digits
    Range: 400 k& Resolution: 100 &
    Accuracy: 1.5 % + 5 digits
    Continuity beeper ( 355 only)
    On at d 30 &
    Off at e 100 &
    Frequency measurement
    Measurement range 5.0 Hz to 1 kHz
    Resolution 0.1 Hz ( 15 Hz to 399.9 Hz) ; 1 Hz ( 400 Hz to 1 kHz)
    Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
    Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
    Trigger level Refer to current and voltage tables

    * Add 2 % to error spec for CF > 2

    General specifications
    Batteries
    Six 1.5 V AA NEDA 15 A or IEC LR6
    Battery life ( with typical usage, backlight off)
    100 hours
    Test leads
    Rated to 1000 V
    Weight
    .814 kg ( 1.8 lb)
    Jaw size
    58 mm ( 2.28 in)
    Dimensions ( LxWxD)
    300 mm x 98 mm x 52 mm ( 12 in x 3.75 in x 2 in)
    Safety rating
    IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

    Environmental specifications
    Operating temperature
    32 ° F to + 122 ° F ( 0 ° C to + 50 ° C)
    Storage temperature
    -4 ° F to 140 ° F ( -20 ° C to + 60 ° C)
    Operating humidity
    0 to 95 % ( non-condensing)
    Operating altitude
    2000 m
    Storage altitude
    10, 000 m
    IP rating
    42 ( indoor use only)
    Drop test requirements
    1 m
    EMI, RFI, EMC
    FCC part 15, IEC/ EN 61326-1: 1997 class B, IEC/ EN 61326: 1997 3V/ m, performance criteria B, EN61325
    Temperature coefficients
    Current: 0.1 % of reading per ° C outside 22 ° C to 24 ° C

    Fluke 353 AC/ DC TRMS CLAMP METER, 2000A, AMPS ONLY
    Includes:
    353 clamp meter
    C43 Soft carrying case
    6 AA batteries
    User manual

    Fluke 355 AC/ DC TRMS CLAMP METER, 2000A
    Includes:
    355 clamp meter
    C43 Soft carrying case
    6 AA batteries
    TL224 1.5 m silicone rubber test leads
    TP2 Test Probes
    AC285 Alligator Clips
    User manual

    Hubungi toko DINS ( Digital Instruments)
    Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
    CP : Irfan Syihabudin
    XL : 081908101888
    AS : 085282731888


Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.