    Digital Multimeter Fluke 117 with Non-Contact voltage Call Irfan 085282731888 / 081908101888

    Feature :
    VoltAlertâ„¢ technology for non-contact voltage detection
    AutoVolt automatic ac/ dc voltage selection
    Low input impedance: helps prevent false readings due to ghost voltage
    Large white LED backlight to work in poorly lit areas
    True-rms for accurate measurements on non-linear loads
    Measures 10 A ( 20 A overload for 30-seconds)
    Resistance, continuity, frequency and capacitance
    Min/ Max/ Average with elapsed time to record signal fluctuations
    Compact ergonomic design for one-handed operation
    Compatible with optional magnetic hanger ( ToolPakâ„¢ ) for hands free operation
    CAT III 600 V safety rated

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
    Fuse for A input 11 A, 1000 V FAST Fuse ( Fluke PN 803293)
    Display
    Digital : 6, 000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating Temperature -10 ° C to + 50 ° C
    Storage Temperature -40 ° C to + 60 ° C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life 400 hours typical, without backlight

    Accuracy Specifications
    DC millivolts
    Range : 600.0 mV
    Resolution : 0.1 mV
    Accuracy : ± ( [ % of reading] + [ counts] ) : 0.5% + 2
    DC volts
    Range/ Resolution: 6.000 V / 0.001 V
    Range/ Resolution: 60.00 V / 0.01 V
    Range/ Resolution: 600.00 V / 0.1 V
    Accuracy : ± ( [ % of reading] + [ counts] ) : 0.5% + 2
    Auto volts
    Range : 600.0 V
    Resolution : 0.1 V
    Accuracy : 2.0 % + 3 ( dc, 45 Hz to 500 Hz)
    4.0 % + 3 ( 500 Hz to 1 kHz)
    AC millivolts1 true-rms
    Range : 600.0 mV
    Resolution : 0.1 mV
    Accuracy : 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
    2.0 % + 3 ( 500 Hz to 1 kHz)
    AC volts1 true-rms
    Range/ Resolution: 6.000 V / 0.001 V
    Range/ Resolution: 60.00 V / 0.01 V
    Range/ Resolution: 600.0 V / 0.1 V
    Accuracy : 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
    2.0 % + 3 ( 500 Hz to 1 kHz)
    Continuity
    Range : 600 &
    Resolution : 1 &
    Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer.
    Ohms
    Range/ Resolution: 600.0 & / 0.1 &
    Range/ Resolution: 6.000 k& / 0.001 k&
    Range/ Resolution: 60.00 k& / 0.01 k&
    Range/ Resolution: 600.0 k& / 0.1 k&
    Range/ Resolution: 6.000 M& / 0.001 M&
    Accuracy : 0.9 % + 1
    Range/ Resolution: 40.00 M& / 0.01 M&
    Accuracy : 5 % + 2
    Diode Test
    Range/ Resolution: 2.000 V / 0.001 V
    Accuracy : 0.9% + 2
    Capacitance
    Range/ Resolution: 1000 nF / 1 nF
    Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F
    Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F
    Range/ Resolution: 9999 ¼ F / 1 ¼ F
    Range/ Resolution: 100 ¼ F to 1000 ¼ F
    Accuracy : 1.9% + 2
    Range/ Resolution: > 1000 ¼ F
    Accuracy : 5% + 20%
    LoZ capacitance
    Range : 1 nF to 500 ¼ F
    Accuracy : 10% + 2 typical
    AC amps true-rms ( 45 Hz to 500 Hz)
    Range/ Resolution: 6.000 A / 0.001 A
    Range/ Resolution: 10.00 A / 0.01 A
    Accuracy : 1.5% + 3
    20 A continuous overload for 30 seconds max
    DC amps
    Range/ Resolution: 6.000 A / 0.001 A
    Range/ Resolution: 10.00 A / 0.01 A
    Accuracy : 1.0% + 3
    20 A continuous overload for 30 seconds max
    Hz ( V or A input) 2
    Range/ Resolution: 99.99 Hz / 0.01 Hz
    Range/ Resolution: 999.99 Hz / 0.1 Hz
    Range/ Resolution: 9.999 Hz / 0.001 Hz
    Range/ Resolution: 50.00 Hz / 0.01 Hz
    Accuracy : 0.1% + 2

    Notes:
    1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V.
    2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe.
    3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
    4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F

    Mechanical & General Specifications
    Size 167 x 84 x 46 mm ( 6.57" x 3.31" x 1.82" )
    Weight 550 g

    Model includes the following:
    4 mm silicone test lead set
    Holster
    User manual

    Hubungi toko DINS ( Digital Instruments)
    Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
    CP : Irfan Syihabudin
    AS : 085282731888
    XL : 081908101888


Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.