    Fluke 345 Power Quality Clamp Meter Call Irfan 085282731888/ 081908101888

    This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

    The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.

    One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyzer ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.

    Besides effectively performing basic tasks like measuring wattage, the Fluke 345 power meters offer the ease of use, portability and flexibility needed to resolve most power issues in commercial, industrial and residential settings.

    Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
    Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
    Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
    Load studies - Verify electrical system capacity before adding loads

    AC/ DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
    Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
    Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
    Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
    Verify batteries: Direct measurement of dc ripple ( % ) for battery and dc systems
    Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
    Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
    Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
    3-Phase power: Built in capability for balanced loads
    View graphs and generate reports: Use power analyzer with included Power Log software

    Display

    Color transmissive LCD 320 x 240 pixels ( 70 mm diagonal) with 2 level backlight

    Power supply

    Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
    Battery life typically
    > 10 hours ( backlight on full)
    > 12 hours ( backlight reduced)
    Battery Eliminator BE345
    Input 110/ 230 V 50/ 60 Hz
    Output 15 V dc, 300 mA

    Ambient conditions ( For indoor use only)
    Reference conditions
    All accuracies stated at 23Ú C ± 1Ú C ( 73.4 ° F ± 1.8 ° F)
    Operating temperature
    0 ° C to 50 ° C ( 32 ° F to 122 ° F)
    Temperature coefficient of current
    d ± 0.15 % of rdg per ° C
    Temperature coefficient of voltage
    d ± 0.15 % of rdg per ° C
    Maximum relative humidity
    80 % for temperatures up to 31 ° C ( 87 ° F) decreasing linearly to 50 % relative humidity at 40 ° C ( 104 ° F)
    Maximum operating altitude
    2000 m

    Electrical safety
    Maximum safe working voltages
    Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2

    Protection IP40; EN60529
    Current measurement
    600 V ac rms or dc between uninsulated conductor and ground
    Voltage measurement
    600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages ( delta power config.)

    EMC
    Emission
    IEC/ EN 61326-1: 1997 class A
    Immunity
    IEC/ EN 61326-1: 1997 Annex C Performance Criterion B

    Mechanical
    Dimensions ( length x width x depth)
    300 mm x 98 mm x 52 mm ( 12 in x 3.75 in x 2 in)
    Weight including batteries
    820 g/ 1.8 lb
    Jaw opening
    60 mm
    Jaw capacity
    58 mm diameter
    Cleaning
    The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.

    Electrical data
    All accuracies stated at 23 ° C ± 1 ° C ( 73.4 ° F ± 1.8 ° F) . See Ambient conditions specifications for temperature coefficients.

    Current measurement ( dc, dc rms, ac rms)
    Measuring range
    0 to 2000 A dc or 1400 ac rms
    Autorange facility
    40 A / 400 A / 2000 A
    Resolution
    10 mA in 40 A range
    100 mA in 400 A range
    1 A in 2000 A range
    Accuracy: DC and dc rms
    I > 10 A: ± 1.5 % rdg ± 5 digits
    I 10 A: ± 3 % rdg ± 5 digits
    I 10 A: ± 5 % rdg ± 5 digits
    I 10 A: ± 2 % rdg ± 5 digits
    I < 10 A: ± 0.5 AHr
    Accuracy: CF ( Crest Factor)
    1.1 d CF < 3: ± 3 % rdg ± 5 digits
    3 d CF < 5: ± 5 % rdg ± 5 digits
    Resolution: 0.01
    Accuracy: RPL ( Ripple)
    2 % d RPL 2 A
    All measurements dc and 15 Hz to 1 kHz
    Maximum overload 10, 000 A or rms x frequency 1 V: ± 1 % rdg ± 5 digits
    V 1 V: ± 3 % rdg ± 5 digits
    V 1 V: ± 5 % rdg ± 5 digits
    V < 1 V: ± 0.03 V
    Accuracy: CF ( Crest Factor)
    1.1 d CF < 3: ± 3 % rdg ± 5 digits
    3 d CF < 5: ± 5 % rdg ± 5 digits
    Resolution: 0.01
    Accuracy: RPL ( Ripple)
    2 % d RPL 0.2 V

    All measurements dc and 15 Hz to 1 kHz
    Maximum overload 1, 000 V rms
    Volts rms is a true-rms measurement ( ac + dc)

    Harmonics
    THD ( Total Harmonic Distortion)
    1 % d THD < 100 % : ± 3 % rdg ± 5 digits
    100 % d THD < 600 % : ± 5 % rdg ± 5 digits
    Resolution: 0.1 %
    DF ( Distortion Factor)
    1 % d DF < 100 % : ± 3 % rdg ± 5 digits
    Resolution: 0.1 %
    H02 d Vharm 1V

    Watts measurement ( single- and three-phase) ( dc, dc rms, ac rms)
    Measuring range
    0 to 1650 kW dc or 1200 kW ac
    Autoranging facility
    4 kW, 40 kW, 400 kW, 1650 kW
    Resolution
    1 W in 4 kW
    10 W in 40 kW
    100 W in 400 kW
    1 kW in 1200 kW
    Accuracy
    2.5 % rdg ± 5 digits
    W1Ø < 2 kW ± 0.08 kW
    W3Ø 2 kVA: 2.5 % rdg ± 5 digits
    VA 4 kVAR: ± 2.5 % rdg ± 5 digits
    VAR < 4 kVAR: ± 0.25 kVAR
    Power factor range
    0.3 < PF 2 kWHr: ± 3 % ± 5 digits
    kWHr < 2 kWHr: ± 0.08 kWHr
    All Watts / VA / VAR / PF measurements
    Frequency range: DC and 15 Hz to 1 kHz
    Current range: 10 A to 1400 A rms
    Voltage range: 1 V to 825 V rms
    Maximum input: 825 V rms/ 1400 A rms
    Maximum overload: 1000 V rms/ 10, 000 A All measurements dc and 15 Hz to 1 kHz. Maximum overload 10, 000 A or rms x frequency 10 A: ± 5 % rdg ± 1 pixel
    I < 10 A: ± 0.5 A
    All measurements dc and 15 Hz to 1 kHz
    Maximum overload
    Maximum overload 10, 000 A or rms x frequency < 400, 000
    Amps rms is a true-rms measurement ( ac + dc)
    Capture time
    1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
    Maximum sampling rate
    15.625 kHz

    Interface

    USB Interface to a PC

    Power Log software for download, analysis and reporting

    345 Upgrade Utility for installing a new firmware version

    Logging Memory
    Logging areas
    Three areas that can be used individually or combined into one large area
    Averaging periods
    1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom

    Logging Times
    Volts and current mode
    Average time Logging time ( 1 area)
    1 s 1 h 49 m
    2 s 3 h 38 m
    5 s 9 h 6 m
    10 s 18 h 12 m
    30 s 2 d 6 h 36 m
    1 min 4 d 13 h 12 m
    5 min 22 d 18 h 0 m
    10 min 45 d 12 h 0 m
    15 min 68 d 6 h 0 m
    Logging time ( 3 areas)
    1 s 5 h 12 m
    2 s 10 h 24 m
    5 s 1 d 2 h 00 m
    10 s 2 d 4 h 00 m
    30 s 6 d 12 h 1 m
    1 min 13 d 0 h 12 m
    5 min 65 d 0 h 15 m
    10 min 130 d 0 h 30 m
    15 min 195 d 0 h 45 m
    V & A harmonics mode
    Average time Logging time ( 1 area)
    1 s 0 h 34 m
    2 s 1 h 8 m
    5 s 2 h 52 m
    10 s 5 h 44 m
    30 s 17 h 13 m
    1 m 1 d 10 h 26 m
    5 m 7 d 4 h 10 m
    10 m 14 d 8 h 20 m
    15 m 21 d 12 h 30 m
    Logging time ( 3 areas)
    1 s 1 h 38 m
    2 s 3 h 16 m
    5 s 8 h 11 m
    10 s 16 h 23 m
    30 s 2 d 1 h 11 m
    1 m 4 d 2 h 23 m
    5 m 20 d 11 h 25 m
    10 m 81 d 0 h 50 m
    15 m 121 d 13 h 15 m
    single- and three-phase power mode
    Average time Logging time ( 1 area)
    1 s 1 h 40 m
    2 s 3 h 21 m
    5 s 8 h 22 m
    10 s 16 h 45 m
    30 s 2 d 2 h 17 m
    1 m 4 d 4 h 35 m
    5 m 20 d 22 h 55 m
    10 m 41 d 21 h 50 m
    15 m 62 d 20 h 45 m
    Logging time ( 3 areas)
    1 s 4 h 47 m
    2 s 9 h 34 m
    5 s 23 h 57 m
    10 s 1 d 23 h 54 m
    30 s 5 d 23 h 25 m
    1 m 11 d 23 h 25 m
    5 m 59 d 21 h 5 m
    10 m 119 d 18 h 10 m
    15 m 179 d 15 h 15 m

    Power Quality Clamp Meter fluke 345
    Includes:
    345 Power Quality Clamp Meter
    Soft carrying case
    Power Log software
    Test leads
    Alligator clips
    Test probes
    USB cable
    International ac adapter / battery eliminator
    Printed English language user manual
    Multi-language manual CD

    Hubungi toko DINS ( Digital Instruments)
    Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
    CP : Irfan Syihabudin
    XL : 081908101888
    AS : 085282731888


Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.