Selamat Datang!
Gabung Sekarang
|
Masuk
Menu Anggota
|
Bantuan
|
0
SEMUA
PRODUK
JUAL
BELI
PERUSAHAAN
Mengenalkan Indotrade.co.id kepada teman
*
artinya harus diisi
*
Nama Anda:
*
Email Anda:
*
Email Teman Anda: :
Untuk mengirim lebih dari satu orang, pisahkan setiap email dengan koma.
Contoh: nama1@domain.co.id, nama2@domain.co.id dan seterusnya
*
Pesan:
Halo, Saya Pebisnis Saya mengenal produk ini dari https://www.indotrade.co.id dan saya lihat hal ini mungkin berguna untuk anda. ------------------------------------------------------- Fluke 117, Digital Multimeter with Non-Contact voltage Call Irfan 085282731888 Digital Multimeter Fluke 117 with Non-Contact voltage Call Irfan 085282731888 / 081908101888 Feature : VoltAlert™ technology for non-contact voltage detection AutoVolt automatic ac/ dc voltage selection Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True-rms for accurate measurements on non-linear loads Measures 10 A ( 20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/ Max/ Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger ( ToolPak™ ) for hands free operation CAT III 600 V safety rated Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse ( Fluke PN 803293) Display Digital : 6, 000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range : 600.0 mV Resolution : 0.1 mV Accuracy : ± ( [ % of reading] + [ counts] ) : 0.5% + 2 DC volts Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.00 V / 0.1 V Accuracy : ± ( [ % of reading] + [ counts] ) : 0.5% + 2 Auto volts Range : 600.0 V Resolution : 0.1 V Accuracy : 2.0 % + 3 ( dc, 45 Hz to 500 Hz) 4.0 % + 3 ( 500 Hz to 1 kHz) AC millivolts1 true-rms Range : 600.0 mV Resolution : 0.1 mV Accuracy : 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) AC volts1 true-rms Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.0 V / 0.1 V Accuracy : 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) Continuity Range : 600 & Resolution : 1 & Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer. Ohms Range/ Resolution: 600.0 & / 0.1 & Range/ Resolution: 6.000 k& / 0.001 k& Range/ Resolution: 60.00 k& / 0.01 k& Range/ Resolution: 600.0 k& / 0.1 k& Range/ Resolution: 6.000 M& / 0.001 M& Accuracy : 0.9 % + 1 Range/ Resolution: 40.00 M& / 0.01 M& Accuracy : 5 % + 2 Diode Test Range/ Resolution: 2.000 V / 0.001 V Accuracy : 0.9% + 2 Capacitance Range/ Resolution: 1000 nF / 1 nF Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F Range/ Resolution: 9999 ¼ F / 1 ¼ F Range/ Resolution: 100 ¼ F to 1000 ¼ F Accuracy : 1.9% + 2 Range/ Resolution: > 1000 ¼ F Accuracy : 5% + 20% LoZ capacitance Range : 1 nF to 500 ¼ F Accuracy : 10% + 2 typical AC amps true-rms ( 45 Hz to 500 Hz) Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy : 1.5% + 3 20 A continuous overload for 30 seconds max DC amps Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy : 1.0% + 3 20 A continuous overload for 30 seconds max Hz ( V or A input) 2 Range/ Resolution: 99.99 Hz / 0.01 Hz Range/ Resolution: 999.99 Hz / 0.1 Hz Range/ Resolution: 9.999 Hz / 0.001 Hz Range/ Resolution: 50.00 Hz / 0.01 Hz Accuracy : 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V. 2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F Mechanical & General Specifications Size 167 x 84 x 46 mm ( 6.57" x 3.31" x 1.82" ) Weight 550 g Model includes the following: 4 mm silicone test lead set Holster User manual Hubungi toko DINS ( Digital Instruments) Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155 CP : Irfan Syihabudin AS : 085282731888 XL : 081908101888 Untuk informasi selengkapnya, silahkan ke http://www.indotrade.co.id/dins/3049907
0.0087 194.163.150.105