Selamat Datang!
Gabung Sekarang
|
Masuk
Menu Anggota
|
Bantuan
|
0
SEMUA
PRODUK
JUAL
BELI
PERUSAHAAN
Mengenalkan Indotrade.co.id kepada teman
*
artinya harus diisi
*
Nama Anda:
*
Email Anda:
*
Email Teman Anda: :
Untuk mengirim lebih dari satu orang, pisahkan setiap email dengan koma.
Contoh: nama1@domain.co.id, nama2@domain.co.id dan seterusnya
*
Pesan:
Halo, Saya Pebisnis Saya mengenal produk ini dari https://www.indotrade.co.id dan saya lihat hal ini mungkin berguna untuk anda. ------------------------------------------------------- Fluke 355/ 353, True-rms 2000 A Clamp Meters Call Irfan 085282731888 Fluke 355 and 353 True-rms 2000 A Clamp Meters Call Irfan 085282731888/ 081908101888 Faeture: Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm ( 2.3 in) jaw capacity is suitable for large or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures ‘ power-on’ surge current with accuracy and repeatability High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool ( 355 only) Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. ( 355 only) Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A large backlit display allows for easy visibility in low-lit areas Use the display hold feature to capture readings even when the display cannot be viewed Use the low-pass filter to smooth out noisy loads and stabilize readings Electrical specifications Current measurement dc and ac 10 Hz to 100 Hz Range : 40 A Resolution: 10 mA Accuracy, A: 1.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF: 2.50 A Trigger Level for Hz Filter ON: 0.50 A Range : 400 A Resolution: 100 mA Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF: 2.5 A Trigger Level for Hz Filter ON: 2.5 A Range : 2000 A; 1400 ac rms Resolution: 1 A Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF: 8 A Trigger Level for Hz Filter ON: 8 A Crest Factor ( 50/ 60 Hz) Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A Current measurement ac 100.1 Hz to 1 kHz Range : 40 A Resolution: 10 mA Accuracy > 10 A : 3.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF : 2.50 A Trigger Level for Hz Filter ON : 0.50 A Range : 400 A Resolution: 100 mA Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF : 2.5 A Trigger Level for Hz Filter ON : 2.5 A Range : 2000 A; 1400 ac rms Resolution: 1 A Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF : 8 A Trigger Level for Hz Filter ON : 8 A Voltage measurement ( 355 only) dc and ac 10 Hz to 100 Hz ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range : 4 V Resolution: 1 mV Accuracy: 1 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V Range : 40 V Resolution: 10 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V Range : 400 V Resolution: 100 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Range : 600 V ac rms Resolution: 1 V Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Range : 1000 V dc Resolution: 1 V Accuracy: 1 % rdg + 5 digits Voltage measurement ( 355 only) ac 100.1 Hz to 1 kHz ( 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range: 4 V Resolution: 1 mV Accuracy: 3 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V Range: 40 V Resolution: 10 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V Range: 400 V Resolution: 100 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Range: 600 V ac rms Resolution: 1 V Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V Ohms measurement ( 355 only) Range: 400 & Resolution: 0.1 & Accuracy: 1.5 % + 5 digits Range: 4 k& Resolution: 1 & Accuracy: 1.5 % + 5 digits Range: 40 k& Resolution: 10 & Accuracy: 1.5 % + 5 digits Range: 400 k& Resolution: 100 & Accuracy: 1.5 % + 5 digits Continuity beeper ( 355 only) On at d 30 & Off at e 100 & Frequency measurement Measurement range 5.0 Hz to 1 kHz Resolution 0.1 Hz ( 15 Hz to 399.9 Hz) ; 1 Hz ( 400 Hz to 1 kHz) Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts Trigger level Refer to current and voltage tables * Add 2 % to error spec for CF > 2 General specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6 Battery life ( with typical usage, backlight off) 100 hours Test leads Rated to 1000 V Weight .814 kg ( 1.8 lb) Jaw size 58 mm ( 2.28 in) Dimensions ( LxWxD) 300 mm x 98 mm x 52 mm ( 12 in x 3.75 in x 2 in) Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III Environmental specifications Operating temperature 32 ° F to + 122 ° F ( 0 ° C to + 50 ° C) Storage temperature -4 ° F to 140 ° F ( -20 ° C to + 60 ° C) Operating humidity 0 to 95 % ( non-condensing) Operating altitude 2000 m Storage altitude 10, 000 m IP rating 42 ( indoor use only) Drop test requirements 1 m EMI, RFI, EMC FCC part 15, IEC/ EN 61326-1: 1997 class B, IEC/ EN 61326: 1997 3V/ m, performance criteria B, EN61325 Temperature coefficients Current: 0.1 % of reading per ° C outside 22 ° C to 24 ° C Fluke 353 AC/ DC TRMS CLAMP METER, 2000A, AMPS ONLY Includes: 353 clamp meter C43 Soft carrying case 6 AA batteries User manual Fluke 355 AC/ DC TRMS CLAMP METER, 2000A Includes: 355 clamp meter C43 Soft carrying case 6 AA batteries TL224 1.5 m silicone rubber test leads TP2 Test Probes AC285 Alligator Clips User manual Hubungi toko DINS ( Digital Instruments) Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155 CP : Irfan Syihabudin XL : 081908101888 AS : 085282731888 Untuk informasi selengkapnya, silahkan ke http://www.indotrade.co.id/dins/3062881
0.0981 194.163.150.105