Selamat Datang di
PUTRA BUANA INSTRUMENT | KYORITSU, FLUKE, MASTECH, GARMIN, ALAT SURVEY, COMPASS, BRUNTON, SUUNTO, LEICA, BOSCH, HT MOTOROLA, RADIO KOMUNIKASI, RADIO RIG, CROSS LINE LASER, NEOLASER, NIVEAU, CALL 02151176451

Anggota Gratis
PUTRA BUANA INSTRUMENT | KYORITSU,  FLUKE,  MASTECH,  GARMIN,  ALAT SURVEY,  COMPASS,  BRUNTON,  SUUNTO,  LEICA,  BOSCH,  HT MOTOROLA,  RADIO KOMUNIKASI,  RADIO RIG,  CROSS LINE LASER,  NEOLASER,  NIVEAU,  CALL 02151176451
PUTRA BUANA INSTRUMENT | KYORITSU, FLUKE, MASTECH, GARMIN, ALAT SURVEY, COMPASS, BRUNTON, SUUNTO, LEICA, BOSCH, HT MOTOROLA, RADIO KOMUNIKASI, RADIO RIG, CROSS LINE LASER, NEOLASER, NIVEAU, CALL 02151176451
Indonesia
  • Jual

    Fluke 1587/ 1577, Insulation Testers Call Irfan 02151176451

    Harga:
    call 02151176451
    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Cara Pembayaran:
    Transfer Bank (T/T), Tunai, Cek Bank
    Kemas & Pengiriman:
    BOX/DUS
    Fluke 1587/ 1577, Insulation Testers Call Irfan 02151176451

    Feature 1587 1577
    Insulation test voltages 50V, 100V, 250V, 500V, 1000V •
    Insulation test voltages 500V, 1000V •
    Insulation test: 0.01 M© to 2.0 G© •
    Insulation test: 0.1 M© to 600 M© •
    Auto discharge of capacitive voltage • •
    Insulation test smoothing reading •
    Frequency •
    Capacitance •
    Diode test •
    Temperature •
    Min/ Max •
    Low pass filter ( for work on VSD' s) •
    AC/ DC Voltage • •
    DC millivolts • •
    AC/ DC milliamps • •
    Resistance ( 0.1 © to 50 M© ) • •
    Continuity • •
    Three-year warranty • •
    Remote probe, test leads, alligator clips • •
    K-type thermocouple •
    Rugged, utility hard case • •
    Auto power off to save battery power • •
    True-rms • •
    Large display with backlight • •
    Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection • •
    CAT III 1000V, CAT IV 600V measurement category • •
    Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work • •

    Specifications
    Voltage DC
    Maximum Voltage: 1000 V
    Accuracy: 1577: ± ( 0.2% + 2)
    1587: ± ( 0.09% + 2)
    Maximum Resolution: 0.001V
    Voltage AC
    Maximum Voltage: 1000 V
    Accuracy: 1577: ± ( 2% + 3)
    1587: ± ( 2% + 3)
    AC Bandwidth: 1587: 5kHz*
    * with low pass filter; 3db @ 800 Hz
    Maximum Resolution: 0.1 mV
    Current DC
    Maximum Amps: 400mA
    Amps Accuracy: 1577: ± ( 1.0% + 2)
    1587: ± ( 0.2% + 2)
    Maximum Resolution: 0.01 mA
    Current AC
    Maximum Amps: 400mA
    Amps Accuracy: 1577: ± ( 2.0% + 2) *
    1587: ± ( 1.5% + 2) *
    * 1kHz bandwidth
    Maximum Resolution: 0.01 mA
    Resistance
    Maximum Resistance: 50 M©
    Accuracy: 1577: ± ( 1.2% + 2)
    1587: ± ( 0.9% + 2)
    Maximum Resolution: 0.1©
    Capacitance( 1587 only)
    Maximum Capacitance: 9, 999 µ F
    Accuracy: ± ( 1.2% + 2)
    Maximum Resolution: 1 nF
    Frequency ( 1587 only)
    Maximum Frequency: 100 kHz
    Accuracy: ± ( 0.1% + 1)
    Maximum Resolution: 0.01 Hz
    Temperature Measurement ( 1587 only)
    -40.0 ° C to 537 ° C
    -40.0 ° F to 998 ° F
    excluding probe
    Diode Test ( 1587 only)
    Range: 6 V
    Resolution: 1 mV
    Accuracy: ± ( 2 % + 1)

    Insulation Test
    Minimum Test Current @ 1k© / V:
    1mA
    Test Voltages:
    1577: 500, 1000 V
    1587: 50, 100, 250, 500, 1000 V
    Maximum Resistance per Test Voltage:
    50V:
    100V:
    250V:
    500V:
    1000V: 1577: 600 M©
    1587: 2 G©
    Maximum Resolution per Test Voltage:
    50V: 0.01 M©
    100V: 0.01 M©
    250V: 0.1 M©
    500V: 0.1 M©
    1000V: 0.1 M©
    Accuracy per Test Voltage:
    50V: ± ( 3 % + 5)
    100V: ± ( 3 % + 5)
    250V: ± ( 1.5 % + 5)
    500V: 1577: ± ( 2.0 % + 5)
    1587: ± ( 1.5 % + 5)
    1000V: 1577: ± ( 2.0 % + 5)
    1587: ± ( 1.5 % + 5) to 600 M© , ± ( 10 % + 3) above 600 M©

    Environmental Specifications
    Operating temperature
    – 20 ° C to + 55 ° C
    Storage temperature
    -40° C to + 60° C
    Humidity ( Without Condensation)
    0% - 95% ( 10 ° C – 30 ° C)
    0% - 75% ( 30 ° C – 40 ° C)
    0% - 40% ( 40 ° C – 55 ° C)
    Operating Altitude
    2000 m

    Safety Specifications
    Overvoltage category
    Complies with ANSI/ ISA 82.02.01 ( 61010-1) 2004, CAN/ CSA-C22.2 NO. 61010-1-04, and IEC/ EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
    Agency Approvals
    2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V

    Mechanical & General Specifications
    Size
    203 x 100 x 50 mm ( with holster)
    Weight
    624 g
    Battery life Alkaline
    Meter use: 1000 hours
    Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M© with a duty cycle of 5 seconds on and 25 seconds off.
    IP Rating
    IP40

    Insulation Multimeter Fluke 1587

    Includes:

    Remote probe
    Test leads
    Alligator clips
    K-type thermocouple
    Hard case
    Four AA alkaline batteries
    Quick Reference Guide
    CD Rom with Manual

    Insulation Multimeter Fluke 1577

    Includes:

    Remote probe
    Test leads
    Alligator clips
    Hard case
    Four AA alkaline batteries
    Quick Reference Guide
    CD Rom with Manual