    Kyoritsu 4200,  Digital Earth Clamp Tester Call Irfan 081908101888

    Kyoritsu 4200, Digital Earth Clamp Tester Call Irfan 081908101888

    Harga:
    Call 02151176451
    Jumlah Pesanan:
    Negara Asal:
    Jepang
    Cara Pembayaran:
    Transfer Bank (T/T), Tunai, Cek Bank
    Kemas & Pengiriman:
    unit

    Keterangan :

    Kyoritsu 4200, Digital Earth Clamp Tester Call Irfan 081908101888

    The earth resistance from 0.05 to 1200© can be measured without the auxiliary earth spikes.
    ( The Multiple Earthing System.)
    • True RMS
    Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
    • Noise Check Function
    A function to detect current, which effects on an earth resistance measurement and display " NOISE " mark on the LCD.
    • Memory function
    Save and display up to 100 measurement data.
    • Data hold function / Buzzer function / Back light function
    • Compliant with Safety Standards of IEC 61010-1 : CAT.IV 300V Pollution degree2
    Note:
    A single earthing can not be measured. ( Only for Multiple Earthing System)

    Function Range Resolution Measuring range Accuracy
    Earth resistance Auto range 20© 0.01© * 0.00~ 20.99© | ± 1.5% ± 0.05©
    200© 0.1© 16.0~ 99.9© | ± 2% ± 0.5©
    100.0~ 209.9© | ± 3% ± 2©
    1200© 1© 160~ 399© | ± 5% ± 5©
    400~ 599© | ± 10% ± 10©
    10© 600~ 1260© ---
    AC current
    ( 50Hz / 60Hz)
    Auto range 100mA 0.1mA 0.0~ 104.9mA | ± 2% ± 0.7mA
    1000mA 1mA 80~ 1049mA | ± 2%
    10A 0.01A 0.80~ 10.49A
    30A 0.1A 8.0~ 31.5A
    Operating system
    Earth resistance function : Constant voltage injection,
    Current detection,
    ( Frequency : Approx.2400Hz)
    Dual Integration
    AC current function : Successive Approximation
    Over-range indication " OL " is displayed when input exceeds the upper limit of a measuring range
    Response time Approx.7 seconds ( Earth resistance)
    Approx.2 seconds ( AC current)
    Sample rate Approx. 1 times per second
    Power source DC6V : R6P ( sizeAA manganese battery) × 4pcs,
    or LR6 ( sizeAA alkaline battery) × 4pcs
    Current consumption Approx. 50mA ( max. 100mA)
    Measurement time Approx. 12 hours ( when R6P is used)
    Approx. 24 hours ( when LR6 is used)
    Auto power-off Turns power off about 10 minutes after the last button operation.
    Applicable standards IEC 61010-1 : 2001 ( CAT.IV 300V Pollution degree2)
    Withstand voltage AC5320Vrms / 5 seconds
    Between the Transformer jaws fitted parts and Case enclosure
    ( except for jaws)
    Conductor size Approx. 32mm max.
    Dimension 246( L) × 120( W) × 54( D) mm
    Weight Approx. 780g ( including batteries)
    Accessories Battery R6P : 4pcs Instruction manual : 1pc
    8304 ( Resister for operation check : 1pc)
    9128 ( Hard case : 1pc)
    • Crest factor < 3 ( 50Hz / 60Hz, peak value shall not exceed 60A)
    * 4 counts or less are corrected to 0.

    Why earth resistance can be found by only clamping it?

    Rx, is defined as earth resistance under test, and R1, R2...Rn are defined as earth resistance of other measuring objects.

    These earth resistances, R1, R2, Rn can be considered that they are connected in parallel.
    And they can be regarded as a combined resistance Rs. The Rs can be regarded small enough against Rx since a combined resistance consists of several resistances. Following is an equivalent circuit diagram of this circuit.

    Voltage V is applied to the object ( Resistance Rx) measured from the voltage injection transformer CT1, and the current I corresponding to the earth resistance is flowed.
    The current I is detected with detection transformer CT2, and object ( Resistance Rx) measured can be put out by the calculation. ( refer to the right diagram