Selamat Datang di
PUTRA BUANA INSTRUMENT | KYORITSU, FLUKE, MASTECH, GARMIN, ALAT SURVEY, COMPASS, BRUNTON, SUUNTO, LEICA, BOSCH, HT MOTOROLA, RADIO KOMUNIKASI, RADIO RIG, CROSS LINE LASER, NEOLASER, NIVEAU, CALL 02151176451

Anggota Gratis
PUTRA BUANA INSTRUMENT | KYORITSU,  FLUKE,  MASTECH,  GARMIN,  ALAT SURVEY,  COMPASS,  BRUNTON,  SUUNTO,  LEICA,  BOSCH,  HT MOTOROLA,  RADIO KOMUNIKASI,  RADIO RIG,  CROSS LINE LASER,  NEOLASER,  NIVEAU,  CALL 02151176451
PUTRA BUANA INSTRUMENT | KYORITSU, FLUKE, MASTECH, GARMIN, ALAT SURVEY, COMPASS, BRUNTON, SUUNTO, LEICA, BOSCH, HT MOTOROLA, RADIO KOMUNIKASI, RADIO RIG, CROSS LINE LASER, NEOLASER, NIVEAU, CALL 02151176451
Indonesia
  • Katalog Produk

    Fluke 1555/ 1550C, Insulation Resistance Testers Call Irfan 02151176451

    Harga:
    call 02151176451
    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Cara Pembayaran:
    Transfer Bank (T/T), Tunai, Cek Bank
    Kemas & Pengiriman:
    unit

    Keterangan :

    Fluke 1555/ 1550C Insulation Resistance Testers Call Irfan 02151176451

    Digital insulation testing up to 10kV

    The new 1555 and redesigned Fluke 1550C insulation resistance testers, offer digital insulation testing up to 10kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1555 and 1550C are perfect tools for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
    Features and benefits:

    Test voltages up to 10 kV provides solutions for all applications
    CAT III 1000 V, CAT IV 600 V safety rating
    Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
    Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
    Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
    Long battery life gives the user over 750 tests between charges
    Automatic calculation of Dielectric Absorption ( DAR) and Polarization Index ( PI) with no additional setup
    Guard system eliminates the effect of surface leakage current on high-resistance measurements
    Large digital/ analog LCD for easy viewing
    Capacitance and leakage current measurement
    Ramp function for breakdown testing
    Resistance measurements up to 2T&
    Timer settings up to 99 minutes for timed tests
    Electrical specifications
    The tester’ s accuracy is specified for one year after calibration at operating temperatures of 0 ° C to 35 ° C. For operating temperatures outside the range ( -20 ° C to 0 ° C and 35 ° C to 50 ° C) , add ± .25 % per ° C, except on the 20 % bands add ± 1 % per ° C.

    Insulation resistance measurement

    Test voltage ( dc)

    Range ( dc)

    Accuracy ( ± reading)
    250 V 50 G© unspecified
    5 %
    20 %
    unspecified
    500 V 200 k©
    200 k© to 10 G©
    10 G© to 100 G©
    > 100 G© unspecified
    5 %
    20 %
    unspecified
    1000 V 200 G© unspecified
    5 %
    20 %
    unspecified
    2500 V 500 G© unspecified
    5 %
    20 %
    unspecified
    5000 V 1 T© unspecified
    5 %
    20 %
    unspecified
    10000 V
    ( 1555 only) 2 T© unspecified
    5 %
    20 %
    unspecified
    Bar graph range 0 to 1 T©
    Insulation test voltage accuracy -0 % , + 10 % at 1 mA load current
    Induced ac mains current rejection 2 mA maximum

    Charging rate for capacitive load

    5 seconds per ¼ F

    Discharge rate for capacitive load

    1.5 s/ ¼ F

    Leakage current measurement

    Range: 1 nA to 2 mA

    Accuracy: ± ( 5 % + 2 nA)

    Capacitance measurement

    Range: 0.01 uF to 15.00 ¼ F

    Accuracy: ± ( 15 % rdg + 0.03 ¼ F)

    Timer

    Range: 0 to 99 minutes

    Resolution Accuracy:
    Setting: 1 minute
    Indication: 1 second

    Live circuit warning

    Warning Range:
    30 V to 660 V ac/ dc,
    50/ 60 Hz

    Voltage Accuracy:
    ± ( 15 % + 2 V)

    General specifications
    Display 75 mm x 105 mm
    Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
    Charger Input ( AC) Charger Input ( AC) 85 V to 250 V ac 50/ 60 HZ 20 VA
    This Class II ( double insulated) instrument is supplied with a Class 1 ( grounded) power cord. The protective earth terminal ( ground pin) is not connected internally. The extra pin is for added plug retention only.
    Dimensions 170 mm x 242 mm x 330 mm ( 6.7 in x 9.5 in x 13 in)
    Weight 3.6 kg ( 7.94 lb)
    Temperature ( operating) -20 º C to 50 º C ( -4 º F to 122 º F)
    Temperature ( storage) -20 º C to 65 º C ( -4 º F to 149 º F)
    Humidity 80 % to 31 º C decreasing linearly to 50 % at 50 º C
    Altitude 2000 m
    Enclosure sealing IP40
    Input overload protection 1000 V ac
    Electromagnetic compatibility EN 61326
    Certifications
    Safety compliance CAT III 1000 V, CAT IV 600 V
    Pollution degree 2

    call irfan 021511476451, email : irfan.syihabudin@ gmail.com
    untuk informasi lebih jelasnya silahkan hubungi marketing kami,
    call : 02151176451
    fax : 021-7302811
    CP : irfan 02151176451
    email : irfan.syihabudin@ gmail.com
    web : http: / / www.buanasurvey.com



Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.