Selamat Datang di
PUTRA BUANA INSTRUMENT | KYORITSU, FLUKE, MASTECH, GARMIN, ALAT SURVEY, COMPASS, BRUNTON, SUUNTO, LEICA, BOSCH, HT MOTOROLA, RADIO KOMUNIKASI, RADIO RIG, CROSS LINE LASER, NEOLASER, NIVEAU, CALL 02151176451

Anggota Gratis
PUTRA BUANA INSTRUMENT | KYORITSU,  FLUKE,  MASTECH,  GARMIN,  ALAT SURVEY,  COMPASS,  BRUNTON,  SUUNTO,  LEICA,  BOSCH,  HT MOTOROLA,  RADIO KOMUNIKASI,  RADIO RIG,  CROSS LINE LASER,  NEOLASER,  NIVEAU,  CALL 02151176451
PUTRA BUANA INSTRUMENT | KYORITSU, FLUKE, MASTECH, GARMIN, ALAT SURVEY, COMPASS, BRUNTON, SUUNTO, LEICA, BOSCH, HT MOTOROLA, RADIO KOMUNIKASI, RADIO RIG, CROSS LINE LASER, NEOLASER, NIVEAU, CALL 02151176451
Indonesia
  • Jual

    Fluke 115 Digital Multimeter Call Irfan 02151176451

    Harga:
    call 02151176451
    Jumlah Pesanan:
    Negara Asal:
    China
    Cara Pembayaran:
    Transfer Bank (T/T), Tunai, Cek Bank
    Kemas & Pengiriman:
    BOX/DUS
    Fluke 115 Digital Multimeter Call Irfan 02151176451

    Digital Multimeter Fluke 115
    Large white LED backlight to work in poorly lit areas
    Resistance and continuity
    Min/ Max/ Average to record signal fluctuations
    CAT III 600 V safety rated
    Safety conformance
    All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜ V listed and VDE.

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
    Display
    Digital: 6, 000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating Temperature -10 ° C to + 50 ° C
    Storage Temperature -40 ° C to + 60 ° C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life 400 hours typical, without backlight

    Accuracy Specifications
    DC millivolts
    Range: 600.0 mV
    Resolution: 0.1 mV
    Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
    DC volts
    Range/ Resolution: 6.000 V / 0.001 V
    Range/ Resolution: 60.00 V / 0.01 V
    Range/ Resolution: 600.00 V / 0.1 V
    Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
    AC millivolts1 true-rms
    Range: 600.0 mV
    Resolution: 0.1 mV
    Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz)
    AC volts1 true-rms
    Range/ Resolution: 6.000 V / 0.001 V
    Range/ Resolution: 60.00 V / 0.01 V
    Range/ Resolution: 600.0 V / 0.1 V
    Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz)
    Continuity
    Range: 600 &
    Resolution: 1 &
    Accuracy: Beeper on 250 & ; detectsopens or shorts of 500 ¼ s or longer.
    Ohms
    Range/ Resolution: 600.0 & / 0.1 &
    Range/ Resolution: 6.000 k& / 0.001 k&
    Range/ Resolution: 60.00 k& / 0.01 k&
    Range/ Resolution: 600.0 k& / 0.1 k&
    Range/ Resolution: 6.000 M& / 0.001 M&
    Accuracy: 0.9 % + 1
    Range/ Resolution: 40.00 M& / 0.01 M&
    Accuracy: 5 % + 2
    Diode Test
    Range/ Resolution: 2.00 V / 0.001 V
    Accuracy: 0.9% + 2
    Capacitance
    Range/ Resolution: 1000 nF / 1 nF
    Range/ Resolution: 10.00 µ F / 0.01 µ F
    Range/ Resolution: 100.0 µ F / 0.1 µ F
    Range/ Resolution: 9999 µ F / 1 µ F
    Range/ Resolution: 100 µ F to 1000 µ F
    Accuracy: 1.9% + 2
    Range/ Resolution: > 1000 µ F
    Accuracy: 5% + 20%
    Lo-Z Capacitance
    Range: 1 nF to 500 µ F
    Accuracy: 10% + 2 typical
    AC amps true-rms ( 45 Hz to 500Hz)
    Range/ Resolution: 6.000 A / 0.001 A
    Range/ Resolution: 10.00 A / 0.01 A
    Accuracy: 1.5% + 3
    20 A overload for 30-seconds max
    DC amps
    Range/ Resolution: 6.000 A / 0.001 A
    Range/ Resolution: 10.00 A / 0.01 A
    Accuracy: 1.0% + 3
    20 A overload for 30-seconds max
    Hz ( V or A input) 2
    Range/ Resolution: 99.99 Hz / 0.01 Hz
    Range/ Resolution: 999.9 Hz / 0.01 Hz
    Range/ Resolution: 9.999 kHz / 0.001 kHz
    Range/ Resolution: 50 kHz / 0.01 kHz
    Accuracy: 0.1% + 2

    Notes:
    1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V.
    2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe.
    3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
    4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F
    2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage

    Mechanical & General Specifications
    Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " )
    Weight 550 g

    Model includes the following:
    Installed 9 V battery
    Test leads
    User manual

    HVAC Multimeter Fluke 116 with Temperature and Microamps Call Irfan 02151176451

    Built-in thermometer for HVAC applications
    Microamps to test flame sensors
    Low input impedance: helps prevent false readings due to ghost voltage
    Large white LED backlight to work in poorly lit areas
    Resistance, continuity, frequency and capacitance
    Min/ Max/ Average with elapsed time to record signal fluctuations
    Compact ergonomic design for one-handed operation
    Compatible with optional magnetic hanger ( ToolPakâ„¢ )
    CAT III 600 V safety rated

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
    Display
    Digital: 6, 000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating Temperature -10 ° C to + 50 ° C
    Storage Temperature -40 ° C to + 60 ° C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life 400 hours typical, without backlight

    Accuracy Specifications
    DC millivolts
    Range: 600.0 mV
    Resolution: 0.1 mV
    Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
    DC volts
    Range/ Resolution: 6.000 V / 0.001 V
    Range/ Resolution: 60.00 V / 0.01 V
    Range/ Resolution: 600.00 V / 0.1 V
    Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
    Auto volts
    Range: 600.0 V
    Resolution: 0.1 V
    Accuracy: 2.0 % + 3 ( dc, 45 Hz to 500 Hz)
    4.0 % + 3 ( 500 Hz to 1 kHz)
    AC millivolts1 true-rms
    Range: 600.0 mV
    Resolution: 0.1 mV
    Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
    2.0 % + 3 ( 500 Hz to 1 kHz)
    AC volts1 true-rms
    Range/ Resolution: 6.000 V / 0.001 V
    Range/ Resolution: 60.00 V / 0.01 V
    Range/ Resolution: 600.0 V / 0.1 V
    Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
    2.0 % + 3 ( 500 Hz to 1 kHz)
    Continuity
    Range: 600 &
    Resolution: 1 &
    Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer.
    Ohms
    Range/ Resolution: 600.0 & / 0.1 &
    Range/ Resolution: 6.000 k& / 0.001 k&
    Range/ Resolution: 60.00 k& / 0.01 k&
    Range/ Resolution: 600.0 k& / 0.1 k&
    Range/ Resolution: 6.000 M& / 0.001 M&
    Accuracy: 0.9 % + 1
    Range/ Resolution: 40.00 M& / 0.01 M&
    Accuracy: 1.5 % + 2
    Diode Test
    Range/ Resolution: 2.000 V / 0.001 V
    Accuracy: 0.9% + 2
    Capacitance
    Range/ Resolution: 1000 nF / 1 nF
    Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F
    Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F
    Range/ Resolution: 9999 ¼ F / 1 ¼ F
    Range/ Resolution: 100 ¼ F to 1000 ¼ F
    Accuracy: 1.9% + 2
    Range/ Resolution: > 1000 ¼ F
    Accuracy: 5% + 20%
    LoZ capacitance
    Range: 1 nF to 500 ¼ F
    Accuracy: 10% + 2 typical
    Temperature2 ( Type-K thermocouple)
    Range/ Resolution: -40 ° C to 400 ° C / 0.1 ° C
    Accuracy: 1% + 102
    Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F
    Accuracy: 1% + 182
    AC ¼ amps true-rms ( 45 Hz to 500 Hz)
    Range/ Resolution: 600.0 ¼ A / 0.1 ¼ A
    Accuracy: 1.0% + 2
    DC ¼ amps
    Range/ Resolution: 600.0 ¼ A / 0.1 ¼ A
    Accuracy: 1.0% + 2
    Hz ( V or A input) 2
    Range/ Resolution: 99.99 Hz / 0.01 Hz
    Range/ Resolution: 999.99 Hz / 0.1 Hz
    Range/ Resolution: 9.999 Hz / 0.001 Hz
    Range/ Resolution: 50.00 Hz / 0.01 Hz
    Accuracy: 0.1% + 2

    Notes:
    1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V.
    2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe.
    3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
    4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F

    Mechanical & General Specifications
    Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " )
    Weight 550 g

    HVAC Multimeter Model includes the following:
    4 mm silicone test lead set
    80BK Integrated Temperature probe
    Holster
    Installed 9 V battery
    User manual

    Informasi selengkapnya
    Hubungi Putra Buana Instrument
    T : 02151176451
    F : 0217302811
    M : 081908101888
    CP : Irfan


Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.co.id. Hak Cipta Dilindungi Undang-undang.