Selamat Datang!
Gabung Sekarang
|
Masuk
Menu Anggota
|
Bantuan
|
0
SEMUA
PRODUK
JUAL
BELI
PERUSAHAAN
Mengenalkan Indotrade.co.id kepada teman
*
artinya harus diisi
*
Nama Anda:
*
Email Anda:
*
Email Teman Anda: :
Untuk mengirim lebih dari satu orang, pisahkan setiap email dengan koma.
Contoh: nama1@domain.co.id, nama2@domain.co.id dan seterusnya
*
Pesan:
Halo, Saya Pebisnis Saya mengenal produk ini dari https://www.indotrade.co.id dan saya lihat hal ini mungkin berguna untuk anda. ------------------------------------------------------- Kyoritsu 6310, Power Quality Analyzer Call irfan 85282731888 Power Quality Analyzer Kyoritsu 6310 Call irfan 085282731888/ 081908101888 The ABC of Power Quality Analyzer Product Catalogue Software Applicable model listApplicable model list • Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value ( short term severity in 10 minutes value) and the Plt value ( long term severity in 2 hours value) can be measured. • 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis. • One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory. • Direct communication with PC via USB cable • Built-in Input / Output Function of external signal enables the signal transmission to alarms. • 2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function. • Pull / Insert of CF card possible whenever on recording under the function of memory backup device. • Can monitor insulation at leakage current by using optional leak clamp sensors. • Built-in Print Screen Function enables to record display screen ( Records 512 screens by using CF card: 1 screen 40KB) . • Can display Waveform and Vector, and can confirm the wiring connection, too. • Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V. * Attention for KEW6310 customers: Flicker measurements are possible with firmware of KEW6310 upgrade ( Ver.2.01) , PC software PQA Master upgrade ( Ver. 2.01) and an optional accessory Flicker sensor KEW8325F. TRUE RMS Wiring connections 1P 2W, 1P 3W, 3P 3W, 3P 4W Measurements and parameters Voltage, Current, Frequency, Active power, Reactive power, Apparent power, Active energy, Reactive energy, Apparent energy, Power factor ( cos ¸ ) , Neutral current, Demand, Harmonics, Quality ( Swell/ Dip/ Instantaneous Stop, Transients/ Over Voltage, Inrush Current, Unbalance Rate, IEC Flicker [ Pst( 1 min) * , Pst, Plt] ) , Phase Advance Condenser ( * Pst can be shown in details for 1 minute intervals.) Other functions Digital output function, External communication function, Scaling function Voltage : Ranges [ RMS] 150 / 300 / 600 / 1000V ( CF: 2.5 or less, 100% or less of each range) Allowable input 10~ 110% of each range ( 1000V range : 20% ~ ) Display ranges 5~ 120% of each range Accuracy | ± 0.3% rdg± 0.2% f.s. ( sine wave, 45~ 65Hz) Current : Ranges [ RMS] 8128 ( 50A type ) : 1 / 5 / 10 / 20 / 50A 8127 ( 100A type ) : 10 / 20 / 50 / 100A 8126 ( 200A type ) : 20 / 50 / 100 / 200A 8125 ( 500A type ) : 50 / 100 / 200 / 500A 8124 ( 1000A type ) : 100 / 200 / 500 / 1000A 8129 ( 3000A type ) : 300 / 1000 / 3000A ( CF: 3.0 or less. 90% or less of each range) Allowable input 10~ 110% of each range Display ranges 1~ 120% of each range Accuracy | ± 0.3% rdg± 0.2% f.s. + Accuracy of Clamp sensor ( sine wave, 45~ 65Hz) Activa power accuracy | ± 0.3% rdg± 0.2% f.s. + Accuracy of Clamp sensor ( Power factor 1, Sine wave, 45~ 65Hz) Influence of power factor | ± 1.0% rdg ( reading at power factor 0.5 against power factor 1) Frequency meter range 40~ 70Hz Internal memory 1.8MB Measurement file ( CSV) : 256kB× 6 blocks ( = 1.536MB) Screen file ( BMP) : 32kB× 7 blocks ( = 0.224MB) Configuration file ( KAS) : 32kB Display 320× 240 ( RGB) Pixel, 3.5-inch color STN display Temperature & humidity range 23º C± 5º C, Relative humidity 85% or less ( no condensation) Storage Temperature & humidity range -20º C± 60º C, Relative humidity 85% or less( no condensation) Operating Temperature & humidity range 0º C± 40º C, Relative humidity 85% or less( no condensation) PC Card type * 1 Compact flash card ( Capacity: 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB) * The CF card larger than 2GB is usable, however, the possible stored size will be limited to 2GB. For example, when the CF card of 4GB or 8GB is used, the maximum stored size will be 2GB. Applicable standards IEC 61010-1 CAT.III 600V Pollution degree 2 IEC 61010-031, IEC 61326 Power supply AC 100V ~ 240V± 10% ( 45~ 65Hz) Alkaline size AA battery LR6 ( 9V 1.5V × 6) or Ni-MH ( HR15-51) Dimension 175( L) × 120( W) × 68( D) mm Weight approx. 900g ( including batteries) Accessories 7141B ( Voltage test lead set) 7148 ( USB cable) 7170 ( Power cord) 9125 ( Carrying case) 8307 ( Compact flash card 128MB) 8319 ( CF Card reader) Input terminal plate ( 6-kind) Alkaline size AA battery ( LR6) × 6 PQA MASTER ( PC Software) Quick manual Cable marker × 32 Optional accessories 8124, 8125, 8126, 8127, 8128 ( Load current clamp sensor) 8129 ( Flexible clamp sensor) 8146, 8147, 8148 ( Leakage & Load current clamp sensor) * 2 8141, 8142, 8143 ( Leakage clamp sensor) * 2 8322 ( Compact flash card 256MB) 8323 ( Compact flash card 1GB) 8312 ( Power supply adaptor) 8325F ( Flicker sensor) 9132 ( Carrying case ( for instrument) ) * 1: Please refer to here for the CF cards which checked. * 2: Cannot be used for power measurement. MODEL Clamp Sensor KEW 6310-01 8125 ( 500A) × 3 KEW 6310-02 8125 ( 500A) × 2 KEW 6310-03 8124 ( 1000A) × 3 KEW 6310-04 8124 ( 1000A) × 2 KEW 6310-05 8126 ( 200A) × 3 KEW 6310-06 8126 ( 200A) × 2 KEW 6310-07 8127 ( 100A) × 3 KEW 6310-08 8127 ( 100A) × 2 KEW 6310-09 8128 ( 5A) × 3 KEW 6310-10 8128 ( 5A) × 2 KEW 6310-11 8129-03 × 1 KEW 6310-12 8129-02 × 1 Accessories 6310 × 1 7141B ( Voltage test lead set) 7148 ( USB cable) 7170 ( Power cord) 9125 ( Carrying case) PQA MASTER ( PC Software) Input terminal plate ( 6-kind) Quick manual Alkaline size AA battery ( LR6) × 6 8307 ( Compact flash card 128MB) Cable marker × 32 8319 ( CF Card reader) Hubungi toko DINS ( Digital Instruments) Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155 CP : Irfan Syihabudin Xl : 081908101888 As : 085282731888 Untuk informasi selengkapnya, silahkan ke http://www.indotrade.co.id/dins/3047083
0.0075 194.163.150.105