Selamat Datang!
Gabung Sekarang
|
Masuk
Menu Anggota
|
Bantuan
|
0
SEMUA
PRODUK
JUAL
BELI
PERUSAHAAN
Mengenalkan Indotrade.co.id kepada teman
*
artinya harus diisi
*
Nama Anda:
*
Email Anda:
*
Email Teman Anda: :
Untuk mengirim lebih dari satu orang, pisahkan setiap email dengan koma.
Contoh: nama1@domain.co.id, nama2@domain.co.id dan seterusnya
*
Pesan:
Halo, Saya Pebisnis Saya mengenal produk ini dari https://www.indotrade.co.id dan saya lihat hal ini mungkin berguna untuk anda. ------------------------------------------------------- Solid and Liquid Waste INCINERATOR IC Series The thermo Q product line covers a wide range of incinerator systems ranging from municipal solid waste to automatic incinerators for infectious medical waste from hospitals and clinics, liquid waste and sludge waste from industrial , as well as industrial solid waste . Multy Chamber Design The thermo Q Incinerator multy chamber design is one of many reasons that thermo Q IC Series Incinerators meet the construction regulations and tough emission rules issued. Extra combustion air is injected into the after burning chambers, ensuring destruction of all unburned particles. This extra flow prevents not only unburned particles, but also flames from escaping the incinerator and cooling down gas entering the chimney. The unique thermo Q systems ensures safe and clean disposal of waste combined with energy recovery systems for various purposes ( e.g. heating, steam production, etc.) saving operational costs. Safety and Reliability Operational advantages No shredding of waste necessary prior to charging Low fly ash carry over Gas tight incinerator casing = no false air inlet = controlled high efficiency combustion process Constant horizontal stirring of the waste in combination with long retention time = no passing of unburned solid material No passing of unburned liquids to ash collection Capable of injecting liquid waste together with solid waste High thermal efficiency = maximum heat recovery Rapid cooling of the flue gases = minimal risk of reformation of dioxins Multiple layers of insulation = low heat radiation to incinerator room Refractory made from high alumina C 1.800 with max. temp. operation 1.800 OC Key Features Our incineration know-how, design and technology, offers important and unique features such as: The safety charging sluice, eliminating The risk of back-fire and smoke escaping to the incinerator room. The special slow transport of ash and stirring of the waste, providing maximum burn out and low fly ash carry over. The integrated ash burn out chamber securing total burn out of the ashes. The special secondary chamber designed to effectively keep a minimum retention time of 2 seconds at the required temperature at all times. The specially designed refractory lining, made from highly chemical resistant pre-cast elements. The design keeps the incinerator' s surface temperature within 25 C above room temperature. The modular design makes it easy to transport and assemble. The fully automatic control system reducing the need for operating personnel and securing a 100% controlled incineration process complying with any applied emission requirement. The above mentioned features are only a few of many that will guarantee you, as customer, successful operation for many years to come. Technical features Capacity range 50 - 1.000 kg/ h Type of Waste Hospitals and clinics Pharmaceutical plants Veterinary facilities Municipal Solid Waste ( MSW) Industrial Waste Shipboard Waste Pathological/ Animal Carcass Waste Other waste types Specific Heat Content of Waste 0 - 40 MJ/ kg - depending on waste type Liquifier Type Atomizing Nozzle with Compress air mix. Incinerator Operating features Batch or Continuously 8 - 24 h/ day Intermittent one or two shift operation Operating Temperatures Primary Chamber: 600 - 850 C Secondary Chamber: min. 800 C - 1.100 C, 1200 C or other minimum tempe- rature depending on regulation Retention time: 2 seconds Flue Gas System - optional Water- or steam boiler with energy recovery system Flue gas treatment system designed according to waste composition and requirements, i.e.: - Dry scrubber - Wet scrubber - Ceramic filter - Or a combination of the above - ID-fan - Stack Control system Fully automatic C/ W temperature display indicator . The thermo Q liquid waste incinerators are custom designed to provide efficient destruction of your waste liquid. When the heating value of the liquid is sufficient, it is burned directly in a high intensity burner eliminating the need for auxiliary fuel except during warm up. Waste liquids which contain insufficient combustibles to be self sustaining are injected into the incinerator' s combustion chamber by various methods. Thermal capacities of up to 6 MM Btu/ hr are available. Ancillary equipment often supplied includes heat recovery boilers and wet gas scrubbing systems. Untuk informasi selengkapnya, silahkan ke http://www.indotrade.co.id/PTMetalindoEEngineer/2216217
0.1059 194.163.150.105