Selamat Datang!
Gabung Sekarang
|
Masuk
Menu Anggota
|
Bantuan
|
0
SEMUA
PRODUK
JUAL
BELI
PERUSAHAAN
Mengenalkan Indotrade.co.id kepada teman
*
artinya harus diisi
*
Nama Anda:
*
Email Anda:
*
Email Teman Anda: :
Untuk mengirim lebih dari satu orang, pisahkan setiap email dengan koma.
Contoh: nama1@domain.co.id, nama2@domain.co.id dan seterusnya
*
Pesan:
Halo, Saya Pebisnis Saya mengenal produk ini dari https://www.indotrade.co.id dan saya lihat hal ini mungkin berguna untuk anda. ------------------------------------------------------- Fluke 317/ 319, True RMS Clamp Meter Call irfan 085282731888 True RMS Clamp Meter Fluke 317/ 319 Clamp Meters call irfan 085282731888 These affordable instruments combine a compact package with a strong feature set: Special 40A high accuracy AC/ DC high measure, 1.6% accuracy, 0.01A resolution Small body and jaws fit perfectly in your hand and into tight places Large, backlit display is easy-to-see in less than ideal conditions In-rush current function ( 319) for measuring starting current for motors, lighting, etc. Measuring current Frequency ( 319) Resolution up to 0.01A and 0.1 V Measures AC/ DC current to 1000 A ( 319) Measures AC/ DC volts to 600 V Resistance measurement to 4000 © Continuity for quick checking of shorts Auto-shut-off maximizes battery life so the meter works when you need it Display hold function One year warranty General Specifications Digital Display 6000 count resolution Low Battery Indication Displays a signal when the batteries are below their required voltage Power Source Three AAA IEC LR03 batteries Clamp Opening Size 1.45 in ( 37 mm) Jaw Diameter 1.45 in ( 37 mm) Dimensions ( L x W x H) 6.39 in x 2.29 in x 1.20 in ( 162.4 mm x 58.25 mm x 30.5 mm) Weight approximately 13.5 oz ( 384 g) ( batteries included) Auto Range Available in Ohms Safety CE EN/ IEC 61010-1 and IEC 61010-2-032 Measurement Category: 600V CAT III 317 Electrical Specifications Current AC Range 40.00 A, 600.0 A Resolution 0.01 A, 0.1 A Accuracy 1.6% ± 6 digit ( 50-60 Hz) { 40 A} 2.5% ± 8 digit ( 60-500 Hz) { 40 A} 1.5% ± 5 digit ( 50-60 Hz) { 600 A} 2.5% ± 5 digit ( 60-500 Hz) { 600 A} Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A AC response rms Current DC Range 40.00 A, 600.0 A Resolution 0.01 A, 0.1 A Accuracy 1.6% ± 6 digit ( 40 A) 1.5% ± 5 digit ( 600 A) Voltage AC Range 600.0 V Resolution 0.1 V Accuracy 1.5% ± 5 digit ( 20-500Hz) AC response rms Voltage DC Range 600.0 V Resolution 0.1 V Accuracy 1% ± 4 digit Resistance Range 400.0 © , 4000 © Resolution 0.1 © , 1 © Accuracy 1% ± 5 digit Continuity d 30 © Inrush Integration time N/ A Frequency Range N/ A Accuracy N/ A Trigger Level N/ A 319 Electrical Specifications Current AC Range 40.00 A, 600.0 A, 1000 A Resolution 0.01 A, 0.1 A, 1 A Accuracy 1.6% ± 6 digit ( 50-60 Hz) { 40 A} 2.5% ± 8 digit ( 60-500 Hz) { 40 A} 1.5% ± 5 digit ( 50-60 Hz) { 600/ 1000 A} 2.5% ± 5 digit ( 60-500 Hz) { 600/ 1000 A} Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A AC response rms Current DC Range 40.00 A, 600.0 A, 1000 A Resolution 0.01 A, 0.1 A, 1 A Accuracy 1.6% ± 6 digit ( 40 A) 1.5% ± 5 digit ( 600/ 1000 A) Voltage AC Range 600.0 V Resolution 0.1 V Accuracy 1.5% ± 5 digit ( 20-500Hz) AC response rms Voltage DC Range 600.0 V Resolution 0.1 V Accuracy 1% ± 4 digit Resistance Range 400.0 © 4000 © Resolution 0.1 © 1 © Accuracy 1% ± 5 digit Continuity d 30 © Inrush Integration time 100 ms Frequency Range 5.0 - 500.0 Hz Accuracy 0.5% ± 5 digit Trigger Level 10 - 100 Hz e 5 A, 5 - 10 Hz, 100 - 500 Hz e 10 A The accuracy specifications aply at 73 ° F ± 41 ° F ( 23 ° C ± 5 ° C) Below 64 ° F and above 82 ° F ( 18 ° C and above 28 ° C) accuracy degrades at ( 0.1) times specification per ° C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. Environmental Specifications Operating Temperature 14° F to 122° F ( -10 ° C to 50 ° C) Storage Temperature -40 ° F to 140 ° F ( -40 ° C to 60 ° C) Operating Humidity Non condensing ( < 50 ° F) ( < 10 ° C) 90 % RH ( 50 ° F to 86 ° F) ( 10 ° C to 30 ° C) 75 % RH ( 86 ° F to 104 ° F) ( 30 ° C to 40 ° C) 45 % RH ( 104 ° F to 122 ° F) ( 40 ° C to 50 ° C) ( Without Condensation) Operating Altitude 1 mile ( 2000 meters) above mean sea level Storage Altitude 7 miles ( 12, 000 meters) above mean sea level IP Rating IP40 Vibration Requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis Drop Test Requirements 3 ft ( 1 m) drop test, six sides, oak floor EMI, RFI, EMC Instrument unspecified for use in EMC field e 0.1 V/ m Temperature Coefficients 0.1x ( specified accuracy) / ° C ( 82° F) ( 28 ° C) Model Name Description Fluke 317/ 319 The Meter ships with: Test Leads Soft Carrying Case Three AAA batteries ( Installed) 317/ 319 User Manual Hubungi DINS ( Digital Instruments) Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu Ciledug - Tangerang 15155 CP : Irfan HP : 081908101888 / 085282731888 Untuk informasi selengkapnya, silahkan ke http://www.indotrade.co.id/dins/1135664
0.0751 194.163.150.105