    PORTABLE PROCESS ANALYZER FOR HELIUM, Model : 334 SERIES, Brand : Nova

    Jumlah Pesanan
    Tambah ke Keranjang
    Negara Asal
    Kanada
    Kenalkan ke teman Anda Masukan ke Produk Rekanan

    Keterangan

    APPLICATIONS
    For checking process helium ( He) concentrations.

    FEATURES
    • Rugged design that is easy to operate
    • Fast warm up and response
    • Long life thermal conductivity cell that provides accurate
    and stable readings
    • Digital meter readout with backlight
    • Modular layout that is easy to maintain
    • Rechargeable ' gel cell' battery operated
    • Built in sample pump
    • Lightweight, compact and easy to use
    • Weatherproof ( WP) cabinet with clear lexan cover

    OPTIONS
    • Recorder outputs of 0-1V or 4-20mA
    • Sample pre-cooler for hot samples
    • Suitcase ( K) style cabinet available
    • AC power only operation
    • Helium alarms with LED
    • Detachable/ portable datalogger

    CALIBRATION
    • Ambient air for zero
    • 100% He calibration gas for span.

    DESCRIPTION
    The Nova 334 Portable He Analyzer has been designed for the detection of He primarily in air or nitrogen.
    However it can be used in some other applications with several background gases present. Consult Nova on
    these applications.
    The thermal conductivity ( T/ C) cell provides a fast and accurate measurement of He. It has an expected life of over 10 years unless contaminated.
    In operation, a built in sample pump draws in the gas sample through the probe, filters, flow meter, and on to the
    T/ C cell. The detected He is displayed on an LCD digital meter which has a switchable back light for use in dark
    areas.
    A rechargeable ' gel cell' battery provides enough power for approximately 8 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included.

    SPECIFICATIONS
    Method of Detection: Temperature compensated thermal conductivity ( T/ C) cell cannot be burned out
    due to loss of flow or changing gases
    Ranges: 0-100% He in air or in N2
    Resolution: ± 0.1% of He
    Accuracy and Repeatability: ± 2% of full scale
    Drift: ± 1% of full scale per week
    Response Time: 90% of final reading in 10 seconds
    Ambient Temperature Range: 55° to 120° F ( 12° to 50° C)
    Linearity: ± 2% of F.S. on He in Air
    Size and Weight: WP style - approx. 10" L x 7½ " H x 6½ " D @ 8 lbs ( 25.5 x 19 x 16.5 cm @ 3.6 kg)
    K style approx. 14" L x 6" H x 10½ " D @ 8 lbs ( 35.5 x 15.2 x 26.6 cm @ 5.5 kg)
    Power: AC/ DC operation. 115VAC 60Hz for recharging ( 220VAC 50Hz available)
    Output Options: 4-20 mA or 0-1 VDC