Selamat Datang di
Prioritas IndotradeTahun ke-17
APPLICATIONS Analysis of carbon dioxide ( CO2) . For checking combustion efficiency, and burner & control performance of furnaces, heaters and boilers. May be used in commercial, industrial and residential settings. FEATURES ⢠Solid state infrared detector ⢠Rugged design that is easy to operate ⢠Fast warm-up and response ⢠Digital readout meter with backlight ⢠Modular layout that is easy to maintain ⢠Rechargeable battery operation ⢠Built-in sample pump, filter, and flowmeter ⢠Continuous condensate removal ⢠Weatherproof ( WP) cabinet with clear Lexan cover ⢠Stainless steel probe with sample hose OPTIONS ⢠Recorder outputs of 0-1V or 4-20 mA ⢠Stack temperature readout ( 302-T) ⢠Special sampling probes ⢠Sample pre-cooler ⢠Suitcase ( K) style cabinet available ⢠AC power only operation ⢠CO2 alarm with LED ⢠Detachable/ portable data logger CALIBRATION ⢠Air for zero ⢠Analyzed CO2 cal gas for span. DESCRIPTION The Nova 302 Series Portable Flue Gas Analyzers have been designed for accuracy, reliability, and ease of use and service. The 302 uses a solid state infra red detector which responds quickly to CO2 present in the flue gas sample. In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flow meter then on to the CO2 detector. The detected CO2 is displayed on an LCD digital meter which has a switchable backlight for use in dark areas. The 302 can optionally indicate net stack temperature ( 302-T) for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable battery provides enough power for about 8 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included. SPECIFICATIONS Method of Detection: Microprocessor based infrared detector for CO2 Ranges Available: 0 - 20.0% CO2 ( other ranges available) Resolution: ± 0.1% CO2 Accuracy and Repeatability: Within ± 2% full scale Drift: Less than 1% full scale per 8 hours of continuous operation Response Time ( T-90) : 30 - 40 seconds Ambient Temperature Range: 32° to 105° F ( 0° to 40° C) Linearity: Better than 1.0% of full scale Size and Weight: WP style - approx. 11½ " L x 8" W x 7¼ " H @ 8 lbs ( 29 x 20 x 18 cm @ 3.6 kg) K style - approx. 14" L x 10½ " W x 6" H @ 12 lbs ( 36 x 27 x 15 cm @ 5.5 kg) Power: AC/ DC operation. 115VAC 60Hz for recharging ( other voltages available) Output Options: 4-20 mA or 0-1 VDC Alarms: High or low CO2 alarm with LED ( optional)