    PORTABLE DEW POINT ANALYZER, Model : 202 Series, Brand : Nova

    Jumlah Pesanan
    Tambah ke Keranjang
    Negara Asal
    Kanada
    Kenalkan ke teman Anda Masukan ke Produk Rekanan

    Keterangan

    APPLICATIONS
    For checking dew points of air, endothermic or exothermic
    atmosphere furnace gases, or other gases.

    FEATURES
    • Standard range of -10° to + 90° F
    ( -23° to + 26° C version available)
    • Rugged design that is easy to operate
    • Use on any non-corrosive gas
    • Long-life dielectric sensor
    • Can be calibrated in the field
    • Bright LED digital readout
    • Built in sample pump, filter, and flow meter
    • Sloped front panel - easy to read from any angle
    • Sensor easily replaced if contaminated
    • Factory calibrated to NIST traceable standards

    OPTIONS
    • Recorder outputs of 0-1V or 4-20mA
    • Calibration kit
    • Rugged weatherproof enclosure ( WP)
    • Carbon potential calculation ( 202-CP)
    • Remote transmitter with flow-thru chamber also available ( 202RT)
    • Output display in relative humidity ( 202RH)

    CALIBRATION
    • Calibration is easy to do in the field using the optional
    calibration kit ( Part no. NDPCK-03) .
    • Alternatively, it can be returned to Nova for a certified
    calibration

    DESCRIPTION
    The Nova 202 Series Portable Dew Point Analyzers have been designed primarily for accurate dew point measurement
    of exothermic and endothermic heat treating atmospheres.
    The dielectric ceramic sensor provides stable and accurate dew point measurements and is not affected by most
    gas compositions, oil vapors, or particulates in the sample.
    A built in sample pump draws in samples that are of insufficient pressure from the process. The sample flow is
    shown on a small rotameter with valve. The analyzer then reads the dew point continuously.

    MODELS
    • 202: AC powered only
    • 202B: rechargeable battery operated.
    • 202RT: remote transmitter with flow through chamber
    • 202RT-PM: same as 202RT but with panel mounted display

    SPECIFICATIONS
    Method of Detection: Dielectric ceramic sensor
    Ranges Available: -10 to + 90° F ( -23 to + 27° C) standard range
    Resolution: ± 0.1° F ( ± 0.1° C) Dew Point, or ± 1° F ( ± 1° C) , switch selectable
    Accuracy and Repeatability: ± 1° F ( ± 1° C) Dew Point
    Drift: ± 1° F ( ± 1° C) Dew Point max.
    Response Time ( T-90) : Less than 30 seconds
    Ambient Temperature Range: 0° to 120° F ( -18° to 49° C)
    Linearity: ± 1° F ( ± 1° C) Dew Point
    Size and Weight: Sloped panel style - approx. 9" L x 8" H x 10" D @ 8 lbs ( 23 x 20 x 25 cm @ 3.6 kg)
    WP style - approx. 11" L x 6" H x 7-1/ 2" D @ 10 lbs ( 25.5 x 19 x 26.6 cm @ 4.5 kg)
    Power: AC/ DC operation. 115VAC 60 Hz for recharging ( other voltages available)
    202RT & RT-PM - 12 to 24 VDC
    Output Options: 4-20 mA or 0-1 VDC

    UNIQUE APPLICATIONS
    The 202 Series should not be used to measure dew points when trace amounts of sulfur trioxide ( SO3) , chlorine ( Cl2) , hydrogen chloride ( HCl) , or ammonia ( NH3) are present.