Portable Flue Gas Analyser A-600 Wohler[9 May. 2011, 5:13:41]
HargaNN
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & PengirimanUnit
Negara AsalJerman
Kenalkan ke teman Anda
Keterangan
Technical Data
Oxygen Concentration ( O² )
• Range : 0… 21.0 Vol.-%
• Accuracy : ± 0.3 Vol.-%

Carbon Monoxid Concentration ( COlow)
• Range : 0… 4, 000 Vol.-ppm
• Accuracy : ± 20 ppm: ( < 400 ppm) , otherwise 5 % of reading

Hydrogen Concentration ( H2)
• Range : 0… 1, 000 Vol.-ppm
• Accuracy : ± 40 ppm ( < 400 ppm) , otherwise 10 % of reading

NO2-measurement ( optional)
• Range : 0...500 ppm
• Accuracy : ± 8 ppm: 0...100 ppm, ± 5% o.r.

SO2-measurement ( optional)
• Range : 0...4, 000 ppm
• Accuracy : ± 25 ppm: 0...500 ppm, ± 5% o.r.

Carbon Monoxid Concentration ( COhigh) ( opt)
• Range : 0… 100, 000 Vol.-ppm
• Accuracy : ± 100 Vol.-ppm ( < 1, 000 ppm) , 10 % of reading

Nitrogen Concentration ( NOV) ( opt)
• Range : 0… 2, 000 Vol.-ppm, ( permanent up to 1, 000 ppm)
• Accuracy : ± 5 ppm ( < 400 ppm) , otherwise 5 % of reading

Draft/ Differential Pressure ( PD)
• Range : ± 150 hPa
• Accuracy : ± 3.0 Pa ( < 100, 0 Pa) , otherwise 3 % of reading
• Resolution : 0.1 Pa

Air temperature ( TL)
• Range : -20.0… 100.0 ° C
• Accuracy : ± 1 ° C

Flue Gas temperature ( TA)
• Range : -10.0… 900.0 ° C
• Accuracy : EN 50379, Part 2

CO² -Calculation
• Range : 0… CO2max
Resolution : 0, 1 %

Stack losses QA
in reference to the selected fuel ( Siegert formula)

Efficiency ·
• Range : 0… 100.0 % condensation is automatically detected
• Accuracy : 0, 10%

Dew point temperature
in reference to selected fuel,
• Resolution : 0.1 ° C
• Condensate : readings in kg/ m3 ( gas) or kg/ l ( Ö l)
• Air speed : approx. 130 m/ s
• Resolution : < 0.4 m/ s
• Air flow : 0...2, 000 m3/ h
• Resolution : approx. 1 m3/ h
• Date/ time : realtime clock with backup battery
• Storage temperature : -20… 50 ° C
• Work temperature : 5… 40 ° C to meet specifications
• Battery hand held : 6 x AA rechargeable batteries or mains supply
• Battery wireless probe : 3 x AA rechargeable batteries or mains supply
• Weight : approx. 1, 200 g
• Size : 240 x 155 x 65 mm ( with docked probe)

Standar Unit 6103 J :
• Sensor : O2, CO, NO, SO2,
• Wö hler A 600 Basic Instrument
• Probe holder with hose assembly
• Ambient Air Temperature probe 11 inch
• Magnetic holder
• PTFE-Cone
• Filter ( 10 pcs.)
• Disc filter ( 1 package)
• Waterstop filter ( 3pcs.)
• Soot test pump Wö hler RP 72 Set
• Wö hler TD 600 high speed printer
• Aluminium case