Selamat Datang di Indotrade.co.id
Masuk | Daftar

Katalog Produk

Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank[25 Jul. 2010, 8:01:05]
Hargahttp://filterpartindonesia.com
Jumlah Pesanan:
Cara PembayaranTunai

Keterangan

Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank

Structural Composite Vessels
The non-corrosive, cost-effective solution for commercial/ industrial water treatment and storage. Structural Composite Pressure Vessels offer fiberglass construction for outstanding performance and durability in harsh chemical enviroments. With capacities up to 1600 gallons and a variety of options, we can tailor a vessel to meet your needs. All Structural Composite Vessels are warranted for 5 years.
Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank
Features Structural Composite Tank
100% composite fiberglass construction
Outstanding performance and durability in harsh chemical environments
Absolutely will not - and cannot - rust
Requires little or no maintenance
Capacities up to 2500 gallons
Factory-backed 5-year warranty
Materials of construction
Polyethylene inner shell
Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank
Design Parameters
Pentair
Safety factor: 4: 1
Minimum burst at 600psi
Tested to 250, 000 cycles without leakage
Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank
NSF
Safety factor: 4: 1
Minimum burst at 600 psi
Tested to 100, 000 cycles without leakage
Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank
ASME
Top/ bottom flange
Safety factor: 5: 1
Minimum burst at 750 psi
Tested to 33, 000 cycles without leakage
Side flange
Safety factor: 6: 1
Minimum burst at 900 psi
Tested to 100, 000 cycles without leakage
Certified to NSF 61 Standards
Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank
Operating Parameters
Maximum operating pressure: 150 psi
Maximum operating temperature: 150° F ( flanged) , 120° F ( threaded)
Filter Tank | Tank Filter | Structural Filter Tank | FRP Tank | Pentair Tank | Wave Cyber Tank | USA Composite Tank | Composite Tank | Fiber Glass Tank | Polyglass Tank

menampilkan 574 dari 712