4/ 5 GAS EXHAUST ANALYZER TEST DONâ T GUESS DRIVEABILITY PROBLEMS Alat untuk monitoring gas emisi kendaraan yang keluar dari knalpot ( HC, CO, CO2, O2 and NO) Hub 021 9600 4947, 0815 7477 4384
Specifications EMS 5002:
⢠Power: 10 -16 VDC ( 110/ 220 VAC 50/ 60 Hz optional )
⢠Ranges:
HC : 0 - 2000 ppm
CO : 0 - 10%
CO2 : 0 - 20%
O2 : 0 - 25%
NO : 0 - 5000 ppm ( Nitric Oxide ) *
⢠Warm up : Less than 10 minutes
⢠Display resolution:
HC : 1 ppm vol.
CO : 0.01% vol.
CO2 : 0.1% vol.
O2 : 0.01% vol.
NO : 1ppm*
⢠Digital display: 3â x 5â LCD Displays all 5 gases, & AFR or LAMDA
⢠Accuracy ( Bar 97 EPA ASM )
HC : 4 ppm HC
CO : 0.06% CO
CO2 : 0.3% CO2
O2 : 0.1% O2
NO : 25 ppm*
⢠Drift : Zero and span drift are less than ± 0.6% of full scale for the first hour and less than ± 0.4% of full scale per hour thereafter.
⢠System response time: 7 seconds to 90% of final reading
⢠Ambient conditions : 35F ( 2C) to 120F ( 45C) , rel. humidity 0-98%
⢠Sample house : 25 feet ( 7.5 m) with QD coupling 150 Degrees Max.
⢠Sample probe : Stainless steel 1200 Degrees F ( replaceable flex tip )
⢠Mass : Approx. : 10 LBS. ( 4.5 Kg )