Selamat Datang di Indotrade.co.id
Masuk | Daftar
Anggota Prioritas Prioritas Indotrade Tahun ke-14
Bahasa :
HACH, ORION, DENVER, EUTECH, VELP SCIENFICA, CORNING, Treff Lab, MMM, pH spear EUTECH, Gyrozen, EUTECH, LUTRON, FAVORIT, JENCON, MEMMERT, HIRAYAMA, ALL AMERICAN, FUNKE GERBER, CRITERION, MMM, SANFIX, ADITEG, TAKEMURA, KERN, BRAND, HANIL, M TOP, TRANS INST
Informasi Kontak
Nama:
Tn. Marketing Lab Division mks [Pemasaran]
E-mail:
Nomor Telpon:
Nomor telpon Tn. Marketing Lab Division mks di Cawang Kavling Jakarta Timur
Nomor Ponsel:
Nomor ponsel Tn. Marketing Lab Division mks di Cawang Kavling Jakarta Timur
Nomor Faks:
Nomor faks Tn. Marketing Lab Division mks di Cawang Kavling Jakarta Timur
Alamat:
JL.Biru Laut No. 124
Cawang Kavling Jakarta Timur 13340
Untuk info harga & brosur silahkan email mksjakarta@ cbn.net.id
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Jual

2100Q Series Portable Turbidimeters Hach
HargaBersaing
Jumlah Pesanan:
Cara PembayaranTunai
Jumlahperunit
Kemas & Pengirimanperunit
Negara AsalAmerika Serikat
The industry' s best portable turbidimeter just got better!

Meets EPA Method 180.1

Single-standard RapidCalTM calibration offers the simplest solution for low-level measurements.
Single-step verification and on-screen assisted calibration eliminates the need to reference complicated manuals.
Optional USB+ Power Module ( LZV813) enables simple data transfer. All data is easily downloaded to any computer, providing superior data integrity and availability.
Exclusive algorithm in the Rapidly Settling TurbidityTM mode provides accurate, repeatable measurements for rapidly settling, difficult-to-measure samples while eliminating the need for redundant measurements and estimating.

Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials ( 20, 100, 800 NTU) , a 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual ( printed and on CD-ROM) , quick start guide, silicone oil and oiling cloth.

Specifications

Measurement Method Ratio turbidimetric determination using a primary nephelometric light
scatter signal ( 90° ) to the transmitted light scatter signal
Regulatory Meets EPA Method 180.1
Lamp Source Tungsten filament lamp
Range 0-1000 NTU
Accuracy ± 2% of reading plus stray light from 0-1000 NTU
Repeatability ± 1% of reading or 0.01 NTU, whichever is greater
Resolution 0.01 NTU on lowest range
Stray Light = 0.02 NTU
Signal Averaging Selectable on or off
Detector Silicon Photodiode
Reading Modes Normal ( Push to Read)
Signal Averaging
Rapidly Settling Turbidity( TM)
Calibration Options Single step RapidCal( TM) for low-level regulatory reporting from 0-40 NTU
Full range calibration from 0-1000 NTU
Calibration to degrees of turbidity
Calibration Logger Records the last 25 successful calibrations
Verification Logger Logs the last 250 successful verifications
Data Logger 500 records
Power Requirement AC 100-240 V, 50/ 60 Hz ( with optional Power or USB+ Power Module)
4 AA alkaline batteries
Rechargeable NiMH ( with optional USB+ Power Module)
Operating Conditions Temperature: 0 to 50 ° C ( 32 to 122 ° F)
Relative Humidity: 0-90% at 30 ° C, 0-80% at 40 ° C, 0-70% at 50 ° C noncondensing
Storage Conditions -40 to 60 ° C ( -40 to 140 ° F) , instrument only
Interface Optional USB
Sample Required 15 mL ( 0.5 oz.)
Sample Cells Round cells, 60 x 25 mm ( 2.36 x 1 in.) , borosilicate glass with screw caps
Dimensions 22.9 x 10.7 x 7.7 cm ( 9.0 x 4.2 x 3.0 in.)
Weight 530 g ( 1.17 lb) without batteries
620 g ( 1.37 lb) with four AA alkaline batteries
Meter Enclosure Rating IP67 ( closed lid, battery and module compartment excluded)
Protection Class Power supply: Class II
Certification CE certified
Warranty 1 year