The HD2127.1 and HD2127.2 are portable instruments with two inputs and a large LCD display. They measure the temperature using immersion, penetration, contact or air probes. The instruments accept input from probes with SICRAM module and Pt100 sensor or probes with direct 4 wire Pt100 sensor. The Pt100 probes are fitted with SICRAM module and the factory calibration settings are already memorized inside. Upon turning on the instrument automatically detects them. The HD2127.2 instrument is a datalogger. It memorizes up to 32, 000 pairs of data which can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0. The storing interval, printing, and baud rate can be configured using the menu. The HD2127.1 and HD2127.2 models are fi tted with an RS232C serial port and can transfer the acquired measurements to a PC or to a portable printer in real time. The Max, Min and Avg function calculates the maximum, minimum or average values; the A-B function calculates the difference of the temperatures measured by the two inputs A and B. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off which can also be disabled. The instruments have IP67 protection degree. INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions ( Length x Width x Height) 185x90x40mm Weight 470g ( complete with batteries) Materials ABS, rubber Display 2x41D2 digits plus symbols Visible area: 52x42mm Operating conditions Working temperature -5� 50° C Storing temperature -25� 65° C Working relative humidity 0� 90% RH without condensation Protection degree IP67 Power Batteries 4 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20¼ A Mains Output mains adapter 9Vdc / 250mA Measuring units ° C - ° F - ° K Security of memorized data Unlimited, independent of battery charge conditions Time Date and time Schedule in real time Accuracy 1min/ month max departure Measured values storage - model HD2127.2 Type 2000 pages containing 16 pairs of samples each Quantity Total of 32000 samples ( channel A + channel B) Storage interval 1s� 3600s ( 1hour) Serial interface RS232C Type RS232C electrically isolated Baud rate Can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/ Xoff Serial cable length Max 15m Immediate print interval 1s� 3600s ( 1hour) USB interface - model HD2127.2 Type 1.1 - 2.0 electrically isolated Connections Input modules for the probes 2 8-pole male DIN45326 connectors Serial interface 8-pole MiniDin connector USB interface - model HD2127.2 8-pole MiniDin connector Mains adapter 2-pole connector ( positive at centre) Measurement of temperature by Instrument Pt100 measurement range -200� + 650° C Pt1000 measurement range -200� + 650° C Ni1000 measurement range -50� + 250° C Resolution 0.01° C in the range ± 199.99° C 0.1° C in the remaining field Accuracy ± 0.01° C Drift after 1 year 0.1° C/ year