The HD2105.1 and HD2105.2 are portable instruments with a large LCD display. They measure the pH and the redox potential ( ORP) in mV. They measure the temperature using Pt100 or Pt1000 immersion, penetration or contact probes. The electrode calibration can be carried out on one, two or three points and the calibration sequence can be chosen from a list of 13 buffers. The temperature probes are fitted with an automatic detection module, with the factory calibration settings already being memorized inside. The HD2105.2 is a datalogger. It memorizes up to 34, 000 pH and temperature samples which can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0. The storing interval, printing, and baud rate can be configured using the menu. The HD2105.1 and HD2105.2 models are fitted with an RS232C serial port and can transfer the acquired measurements in real time to a PC or to a portable printer. The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the Auto-HOLD function, and the automatic turning off that can also be disabled. The instruments have IP67 protection degree. INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions ( Length x Width x Height) 185x90x40mm Weight 470g ( complete with batteries) Materials ABS, rubber Display 2x41D2 digits plus symbols Visible area: 52x42mm Operating conditions Operating temperature -5⦠50° C Warehouse temperature -25⦠65° C Working relative humidity 0⦠90% RH without condensation Protection degree IP67 Power Batteries 4 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20¼ A Mains Output mains adapter 9Vdc / 250mA Security of memorized data Unlimited, independent of battery charge conditions Time Date and time Schedule in real time Accuracy 1min/ month max departure Measured values storage - model HD2105.2 Type 2000 pages containing 17 samples each Quantity Total of 34000 samples Storage interval 1s⦠3600s ( 1hour) Serial interface RS232C Type RS232C electrically isolated Baud rate Can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/ Xoff Serial cable length Max 15m Immediate print interval 1s⦠3600s ( 1hour) USB interface - model HD2105.2 Type 1.1 - 2.0 electrically isolated Connections Input module for the temperature probes 8-pole male DIN45326 connector pH/ mV input Female BNC Serial interface and USB 8-pole MiniDin connector Mains adapter 2-pole connector ( positive at centre) Measurement of pH by Instrument Measurement range -2.000⦠+ 19.999pH Resolution 0.01 or 0.001pH selectable from menu Accuracy ± 0.001pH Input impedance > 1012© Calibration error @ 25° C Offset> 20mV Slope63mV/ pH Sensitivity 106.5% Measurement of mV by Instrument Measurement range -1999.9⦠+ 1, 999.9mV Resolution 0.1mV Accuracy ± 0.1mV Drift after 1 year 0.5mV/ year Measurement of temperature by Instrument Pt100 measurement range -200⦠+ 650° C Pt1000 measurement range -200⦠+ 650° C Ni1000 measurement range -50⦠+ 250° C Resolution 0.1° C Accuracy ± 0.1° C Drift after 1 year 0.1° C/ year