Selamat Datang di Indotrade.co.id
Masuk | Daftar

Selamat Datang di

MIKASE LABORATORY - PT MITRA KATIGA SEJAHTERA / SUPPLIER ALAT UJI KUALITAS UDARA, AIR, CUACA , KEBISINGAN SERTA GETARAN

http://indotrade.co.id/mikaselaboratory/

Anggota Prioritas Prioritas Indotrade
Tahun ke-17

menampilkan 103 dari 233
  • Katalog Produk

    AIR SPEED AND FLOW RATE - TEMPERATURE TEMPERATURE/ RELATIVE HUMIDITY - PRESSURE, Model : DO2003, Brand : DeltaOhm

    Jumlah Pesanan
    Tambah ke Keranjang
    Negara Asal
    Italia
    Kenalkan ke teman Anda Masukan ke Produk Rekanan

    Keterangan

    DO2003 is a portable instrument, datalogger specially designed to be used in
    the fields of air-conditioning, heating, ventilation, environmental comfort, energy
    saving both for industrial and residential application by means of a complete probes series. It measures: • Air speed and flow rate inside pipeline with hot-wire probes, vane probes or Pitot tube probes
    • relative humidity and temperature with combined probes
    • differential pressure up to 2000 mbar and barometric pressure
    • temperature with immersion, pointed or contact probes.
    This datalogger stores up to 12.000 readings which can be downloaded to a PC connected to the instrument through RS232C serial port. Storage interval, printing, baud rate can be configurated on the menu. “ Record” ( RCD) function calculates maximum, average and minimum values. A big size dual display and a led series make the reading of data easy.
    The instrument is provided also with these further functions: relative measurement, Hold function, zero correction for differential pressure probes and hot-wire
    probes.

    CHARACTERISTICS OF THE INSTRUMENT
    Display: 31D2 digit, dual LCD, figure height 12, 5 mm. Unit of measure and other additional information are supplied with a led series.
    No. 2 inputs: input A for air speed and pressure probes, input B only for combined temperature/ humidity probes. Storage capacity: 12.000 readings.
    Storage interval and printing can be configured between 1 second and 1 hour.
    Safety of stored data and battery charge situation unrelated.
    Automatic switch-off after 8 minutes can be disabled.
    Operating conditions:
    Working temperature: -5° C..50° C. Relative humidity 0-90% RH. not condensing. Storage temperature: -20° C..+ 60° C. Power supply: four 1.5V alkaline AA batteries, , operating time with alkaline batteries 100 hours approx. Probes input: 2 circular 8 pole DIN 45326 male connectors.
    9 pole SUB D male RS232C serial output. Baud rate from 300 to 38400 baud. housing: ABS. Dimensions and weight: 72x210x40 mm - 320gr.