Selamat Datang di
Prioritas IndotradeTahun ke-17
The HD2103.1 and HD2103.2 are portable instruments with a large LCD display. They are designed for use in the fields of air conditioning, heating, ventilation and environmental comfort. They use hot-wire or vane probes to measure air speed, fl ow rate, and temperature inside pipelines and vents. Temperature only is measured by immersion, penetration or air contact probes. The temperature sensor used can be chosen from the Pt100, Pt1000 or Ni1000. The probes are fitted with the SICRAM module, with the factory calibration settings already being memorized inside. The HD2103.2 instrument is a datalogger. It memorizes up to 38, 000 samples which can be transferred from the instrument connected to a PC via the multistandard RS232C serial port and USB 2.0. The storing interval, printing, and baud rate can be configured using the menu. The HD2103.1 and HD2103.2 models are fi tted with an RS232C serial port and can transfer the acquired measurements in real time to a PC or to a portable printer. The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off that can also be disabled. The instruments have IP67 protection degree. INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions ( Length x Width x Height) 185x90x40mm Weight 470g ( complete with batteries) Materials ABS, rubber Display 2x41D2 digits plus symbols Visible area: 52x42mm Operating conditions Operating temperature -5⦠50° C Warehouse temperature -25⦠65° C Working relative humidity 0⦠90% RH without condensation Protection degree IP67 Power Batteries 4 1.5V type AA batteries Autonomy ( * ) 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20¼ A Mains Output mains adapter 9Vdc / 250mA Measuring units ° C - ° F - m/ s - km/ h - ft/ min - mph - knot - l/ s m3/ s - m3/ min - m3/ h - ft3/ s ft3/ min - WCT Security of memorized data Unlimited, independent of battery charge conditions Time Date and time Schedule in real time Accuracy 1min/ month max departure Measured values memorization - model HD2103.2 Type 2000 pages containing 19 samples each Quantity Total of 38000 samples Storage interval 1s⦠3600s ( 1hour) Serial interface RS232C Type RS232C electrically isolated Baud rate Can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/ Xoff Serial cable length Max 15m Immediate print interval 1s⦠3600s ( 1hour) USB interface - model HD2103.2 Type 1.1 - 2.0 electrically isolated Connections Input module for the probes 8-pole male DIN45326 connector Serial interface and USB 8-pole MiniDin connector Mains adapter 2-pole connector ( positive at centre) Itâ s referred to all the probes except the hot wire ones, which autonomy is stated in the next pages Measurement of temperature by Instrument Pt100 measurement range -200⦠+ 650° C Pt1000 measurement range -200⦠+ 650° C Ni1000 measurement range -50⦠+ 250° C Resolution 0.1° C Accuracy ± 0.1° C Drift after 1 year 0.1° C/ year