Selamat Datang di
Prioritas IndotradeTahun ke-17
CHARACTERISTICS The HD9008TR and HD9009TR are single block RH and temperature microprocessor transmitters, temperature configurable. The HD9008TR is a passive transmitter with a 4⦠20mA output and 7⦠30Vdc power supply; the HD9009TR is a transmitter with a 0⦠1V standard voltage output ( other outputs available on demand) and 7⦠30Vdc power supply. Sensors are mounted at the end of a plastic tube: a capacitive humidity sensor and a Platinum temperature sensor ( 100© @ 0° C) . The instrument can be reprogrammed by means of a key, and no jumper or potentiometer actions are required. The humidity input can be recalibrated by using two saturated solutions: the fi rst one at 75% , the second one at 33% ; the 0% RH⦠100% RH relative humidity range is fi xed, 4mA ( or 0Vdc) correspond to 0% RH, 20mA ( or 1Vdc) equal 100% RH. Temperature standard confi guration is â 40⦠+ 80° C for the HD9008TR for the HD9009TR, corresponding to 4⦠20mA and 0⦠1Vdc, respectively. The user can configure the temperature output in ranges different from the standard one by means of a Pt100 simulator or of a set of fixed resistances, provided that it is included in the -40° C⦠+ 80° C range with a minimum amplitude of 25° C. Two LEDs give alarm indications ( temperature exceeding set range, sensor breakage or short-circuit) and help the operator when programming. An out-of-standard temperature operating range can be requested when placing the order. Important Warning: probes work in the -40° C⦠+ 80° C temperature range. Outside this range data are not correct; electronics is designed to operate in this range. Characteristics HD9007 Luran S777K ( BASF) antistatic UV-resistant thermoplastic material with low thermal conductivity and high reflection. White power-painted anticorodal aluminium support bracket. Stainless steel U-bar mounting bracket for shafts from 25 to 44mm. Dimensions: external à : 130 mm. Height, excluding bracket: HD9007 A1: 190 mm, weight: 640 gr. HD9007 A2: 240 mm, weight: 760 gr. Sensor fixing ring nuts: à 27 mm, à 25 mm on demand when ordering. HD9007 ring-shield is suitable to protect temperature and RH/ temperature sensors used in weather stations from solar radiations, rain and wind. TECHNICAL DATA HD9008TR HD9009TR Electronics Working Temperature -40⦠+ 80° C Sensor Working Temperature -40⦠+ 80° C Transmitter Power Supply 7⦠30Vdc ( 4⦠20mA) 7⦠30Vdc ( 2mA) Capacity 300 pF typ. HUMIDITY Measuring Range 5⦠98% RH Accuracy at 20° C ± 2% RH ( 5⦠90% RH) ± 2.5% RH ( for the remaining range values) Response time at 63% of final variation 3 min. with filter; 6s without filter Output Signal 0% RH = 4.0mA 100% RH = 20.0mA 0% RH = 0.00 Vdc 100% RH = 1.00 Vdc ( * ) Load Resistance RLmax= ( Vdc - 7) 22mA RinMIN= 10k© TEMPERATURE Measuring Range â Standard Configuration - ( * * ) -40⦠+ 80° C -40⦠+ 80° C Accuracy ± 0.1° C ± 0.1% of measurement Response time at 63% of final variation 60s with fi lter; 5s without filter Output Signal -40° C = 4.0mA + 80° C = 20.0mA -40° C = 0.00 Vdc + 80° C= 1.00 Vdc ( * ) Load Resistance RLmax= ( Vdc - 7) 22mA RinMIN= 10k© Dimensions à 26 x 225mm Cable Dimensions Maximum Length ( * * * ) 200m 10m Wire Min. Section 20 AWG - 0.5mm2 20 AWG - 0.5mm2 Cable Max. Diameter à 5mm à 5mm