Keterangan
APPLICATIONS
For continuous analysis of sulfur dioxide ( SO2) in process gas streams
using an infrared detector. Percent and PPM levels available as Models
460 & 460L respectively.
FEATURES
⢠Percent ( 460) or PPM ( 460L) SO2 by infrared detector
⢠Detector is sensitive, reliable, and non-depleting
⢠Bright digital readout
⢠Fast response ( T90 - less than 15 seconds)
⢠Microprocessor control for push button calibration
⢠Easy-to-maintain modular layout
⢠Built in sample pump, flowmeter, and filters
⢠4 - 20 mA outputs
OPTIONS
⢠Hi/ Low gas, low flow, and diagnostic alarms available
⢠Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
⢠Sample conditioning systems available for removal of moisture, acidic gas, and dust
⢠Cabinet purge system available for use in hazardous areas
⢠One-step ' cal-now' button with touch screen LCD display
⢠Full automatic calibration with touch screen LCD display
⢠Cold weather package for operation to -5° F ( -20° C)
⢠Cabinet coolers can be fitted to most models
⢠Sensors mounted in temperature controlled heated box to improve accuracy
⢠High temperature filters and probes
CALIBRATION
⢠Easily zero checked on ambient air
⢠Span using a known SO2 in nitrogen ( N2) calibration gas.
DESCRIPTION
The Nova 460 Series SO2 analyzers utilize a reliable microprocessor-based non-dispersive infrared detecter
specific to SO2. In operation, the internal sample pump draws the sample gas through the filter/ condensate trap, secondary filter, flow meter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM SO2 on the digital meter. The output is also available as an analog or digital signal.
MODELS
There are seven types of mounting configurations available :
⢠460N4 - Wall mounted NEMA4 ( IP65) enclosure rating
⢠460N4X - Wall mounted corrosion-resistant NEMA4X
( IP65) enclosure rating
⢠460N12 - Wall mounted NEMA12 ( IP52) enclosure rating
⢠460PM - Panel mounted, slides open for easy access
⢠460RM - 19" ( 483mm) rack mounted, on sliding rails
⢠460N7MC: Wall mounted NEMA7 UL/ CSA explosion-proof with non-intrusive magnetic calibration, Class 1 Div 1 Group BCD
⢠460PMN7: Wall mounted NEMA7 sensor housing with panel
mounted control cabinet ( two separate enclosures)
SPECIFICATIONS
Method of Detection : Microprocessor-based single cell NDIR
Ranges Available : 460L - 0-1000, 0-3000, 0-5000, PPM SO2 ( PPM versions not currently avail. in N7 exp-proof enclosure) 460 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% SO2
Resolution : 0.1% SO2 on % versions, 10 PPM SO2 on PPM versions
Accuracy and Repeatability : 1% of full scale
Drift : Less than 2% of full scale per month.
Response Time ( T-90) : Less than 15 seconds
Ambient Temperature Range : 40-122° F ( 5-50° C) . Lower temperatures ( -20° C, -5° F) with Cold Weather Package.
Linearity : ± 1% of full scale
Size and Weight : Physical data will vary depending on enclosure style and options required
Power : 115VAC 60Hz ( 220VAC 50Hz available)
Output Options : 4-20ma into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485, MODBUS, Ethernet outputs optional
Alarms : High and/ or low alarm contacts available, relay contacts SPDT 5A @ 220VAC rating.
Low flow alarm optional