    GasAlert Extreme Specifications
    Size 1.1 x 2.0 x 3.75 in. / 2.8 x 5.0 x 9.5 cm
    Weight 2.9 oz. / 82 g
    Alarms - Visual, vibrating, audible (95dB)
    - Low, High, STEL, TWA
    Tests Sensor integrity, circuitry, battery and audible/visual alarms
    on activation, battery (continuous)
    Pump Compatible with the Sampler motorized pump
    Typical battery
    life
    2 year battery life (typical) with replaceable 3V battery
    User options Confidence beep
    Latching alarms
    Stealth mode
    Passcode protection
    Automatic O2 Calibration
    Datalogger Sampling Rate
    Automatic backlight
    User-settable calibration gas
    level
    Calibration past due lockout
    Language choices (5)
    Adjust clock
    Ratings EMI/RFI: Complies with EMC Directive 89/336/EEC
    IP 66/67
    Certifi cations and
    approvals
    h Class I, Div. 1, Gr. A, B, C, D
    Class II, Div. 1, Gr. E, F, G
    American Bureau of Shipping
    ATEX: X g II 1 G T4
    Ex ia IIC T4
    IECEx: Ex ia IIC T4
    X: European Conformity
    Warranty Full 2 year warranty including sensors
    (1 year NH3 sensor)
    Sensor Specifications
    Gas
    Measuring
    Range (ppm)
    Operating
    Temperature
    Relative
    Humidity
    (non-condensing)
    H2S 0-100 -40 to +122°F/-40 to +50°C 15% - 90%
    H2S (High Range) 0-500 -40 to +122°F/-40 to +50°C 15% - 90%
    SO2 0-100.0 -40 to +122°F/-40 to +50°C 15% - 90%
    HCN 0-30.0 -40 to +122°F/-40 to +50°C 15% - 90%
    CO 0-1000 -22 to +122°F/-30 to +50°C 15% - 90%
    CO (Low H2) 0-1000 -22 to +122°F/-30 to +50°C 15% - 90%
    NH3 0-100 -4 to +104°F/-20 to +40°C 15% - 90%
    NH3 (High Range) 0-400 -4 to +104°F/-20 to +40°C 15% - 90%
    Cl2 0-50.0 -4 to +122°F/-20 to +50°C 10% - 95%
    NO 0-250 -4 to +122°F/-20 to +50°C 15% - 90%
    NO2 0-100 -4 to +122°F/-20 to +50°C 15% - 90%
    PH3 0-5.0 -4 to +122°F/-20 to +50°C 15% - 90%
    ETO 0-100.0 -4 to +122°F/-20 to +50°C 15% - 90%
    ClO2 0-1.0 -4 to +122°F/-20 to +50°C 15% - 95%
    O3 0-1.0 -4 to +122°F/-20 to +50°C 15% - 90%
    O2 (%by Vol.) 0-30.0% -4 to +122°F/-20 to +50°C 0% - 99%
    Alarm set points for all sensors are user adjustable. Set point(s) are automatically displayed
    during instrument start up.