HIOKI 3290 & 3290-10CLAMP ON AC/ DC HiTESTER[31 May. 2011, 23:27:13]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Negara AsalJepang
Model : 3290 & 3290-10CLAMP ON AC/ DC HiTESTER

Clamp Meters( Current Meters -for AC/ DC, two ways type-)

All the Functions You Need for Measurement at DC or 1Hz and Up

Choice of three sensors ( Example combinations)
3290/ 3290-10 + 9691 : Measure up to 100A
3290/ 3290-10 + 9692 : Measure up to 200A
3290/ 3290-10 + 9693 : Measure up to 2000A

Choice of measurement methods
DC ( for battery measurement)
AC+ DC RMS ( for full-/ half-wave rectification measurement)
AC RMS ( for current distortion measurement)
PEAK ( for peak value measurement) of inrush current, etc.)

Choice of output ( Simultaneous output)
Effective value output, frequency output, waveform output

3290-10 Functions
Current integral measurement
( obtain polarity-specific integrated DC values)
Operating time/ duty measurement

Basic specifications ( Accuracy guaranteed for 1 year)

3290
Measurement method :
DC, AC+ DC ( True RMS) , AC ( True RMS/ Average rectified)
Peak value display :
Absolute value ( of waveform peak)
Separate AC from DC output :
Separate constituent element of AC, DC
Output ( terminal 1) :
Current waveform or true RMS value ( 2 V / setting range) , Frequency value ( 1 VDC / setting range)
Output ( terminal 2) :
Rms current/ Low-battery warning switch
Integral current measurement :
None
Rate measurement :
None
Timer settings :
None
Data storage :
None
Basic accuracy at DC current :
20.00/ 100.0A ( using the 9691 sensor) : ± 1.3 % rdg. ± 0.10 A/ ± 0.5 A
20.00/ 200.0A ( using the 9692 sensor) : ± 1.3 % rdg. ± 0.10 A/ ± 0.5 A
200.0/ 2000A ( using the 9693 sensor) : ± 1.8 % rdg. ± 1.0 A/ ± 5 A
Basic accuracy at AC current :
20.00/ 100.0A ( using the 9691 sensor) : ± 1.3 % rdg. ± 0.08 A/ ± 0.3 A
( 45 to 66 Hz) :
20.00/ 200.0A ( using the 9692 sensor) : ± 1.3 % rdg. ± 0.08 A/ ± 0.3 A
200.0/ 2000A ( using the 9693 sensor) : ± 1.3 % rdg. ± 0.8 A/ ± 3 A
Voltage measurement :
None
Frequency measurement :
1.00Hz to 1000Hz, Basic accuracy: ± 0.3% rdg. ± 1dgt.
Crest factor :
2.5 or later, or rated peak value of sensor
Frequency characteristic :
DC, or 1 Hz to 1 kHz ( accuracy guaranteed range)
At monitor output: based on the using sensor
Other functions :
Selectable of responce time, filter ( fc= 550 Hz)
Power supply :
LR6 ( AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/ -03 ( The 3290-10 only: external power supply possible)
Dimensions, mass :
155 mm ( 6.10 in) W × 98 mm ( 3.86 in) H × 47 mm ( 1.85 in) D, 545 g ( 19.2 oz)
Supplied accessories :
Carrying strap × 1, LR6 ( AA) alkaline batteries × 4

3290-10
Measurement method :
DC, AC+ DC ( True RMS) , AC ( True RMS)
Peak value display :
Polarities independently ( ± peak value of waveform, in DC mode)
Separate AC from DC output :
None
Output ( terminal 1) :
Current waveform or true RMS value ( 2 V / setting range)
Output ( terminal 2) :
Current integral value ( 1 VDC / setting range)
Integral current measurement :
± , + , - integral, average value
Rate measurement :
Operating time rate, total measurement time
Timer settings :
99 hr, 59 min. ( for repeated up to 20 times)
Data storage :
Peak, integral value, operating time rate, or other
Basic accuracy at DC current :
20.00/ 100.0A ( using the 9691 sensor) : ± 1.3 % rdg. ± 0.10 A/ ± 0.5 A
20.00/ 200.0A ( using the 9692 sensor) : ± 1.3 % rdg. ± 0.10 A/ ± 0.5 A
200.0/ 2000A ( using the 9693 sensor) : ± 1.8 % rdg. ± 1.0 A/ ± 5 A
Basic accuracy at AC current :
20.00/ 100.0A ( using the 9691 sensor) : ± 1.3 % rdg. ± 0.08 A/ ± 0.3 A
( 45 to 66 Hz) :
20.00/ 200.0A ( using the 9692 sensor) : ± 1.3 % rdg. ± 0.08 A/ ± 0.3 A
200.0/ 2000A ( using the 9693 sensor) : ± 1.3 % rdg. ± 0.8 A/ ± 3 A
Voltage measurement :
None
Frequency measurement :
1.00Hz to 1000Hz, Basic accuracy: ± 0.3% rdg. ± 1dgt.
Crest factor :
2.5 or later, or rated peak value of sensor
Frequency characteristic :
DC, or 1 Hz to 1 kHz ( accuracy guaranteed range)
At monitor output: based on the using sensor
Other functions :
Selectable of responce time, filter ( fc= 550 Hz)
Power supply :
LR6 ( AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/ -03 ( The 3290-10 only: external power supply possible)
Dimensions, mass :
155 mm ( 6.10 in) W × 98 mm ( 3.86 in) H × 47 mm ( 1.85 in) D, 545 g ( 19.2 oz)
Supplied accessories :
Carrying strap × 1, LR6 ( AA) alkaline batteries × 4