Anggota Gratis 
Bahasa :
PT. BUMI INDONESIA ( WWW.TOKOSURVEY.COM) - ( 0541) 7150401 / 0811590455 ( SAMARINDA) DEALER RESMI GARMIN KALIMANTAN
http://indotrade.co.id/cv_bumi_indonesia/
PT. BUMI INDONESIA ( WWW.TOKOSURVEY.COM)   ( 0541) 7150401 / 0811590455 ( SAMARINDA) DEALER RESMI GARMIN KALIMANTAN
Informasi Kontak
Nama:
Tn. H. Akhmad Munawir Adam [Pemilik/Pengusaha]
E-mail:
Situs Web:
Nomor Telpon:
Nomor telpon Tn. H. Akhmad Munawir Adam di samarinda
Nomor Ponsel:
Nomor ponsel Tn. H. Akhmad Munawir Adam di samarinda
Nomor Faks:
Nomor faks Tn. H. Akhmad Munawir Adam di samarinda
Alamat:
JL.Tantina I No 26 samarinda
samarinda 75117, Kalimantan Timur
Indonesia
DEALER RESMI GPS Garmin, jual sewa/ rental service kalibrasi Total station Theodolite Nikon Topcon Sokkia wilayah Kalimantan. Jasa Survey Topografi, mining service, rental alat survey, balikpapan banjarmasin palangkaraya tanah grogot tarakan tenggarong
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

KYORITSU 4105A Grounding Tester / Earth Tester 0541) 7150401 / 0811590455 samarinda balikpapan kalimantan
HargaCall
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T), Tunai
Kemas & PengirimanBaru, Bergaransi
Negara AsalJepang

Keterangan

KYORITSU 4105A Grounding Tester / Earth Tester

Dust and drip proof.( designed to IEC 529 IP54)
• In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
( unit can be hung from the neck for simplified measurement)
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

Measurement
Ranges Earth Resistance: 0~ 20© / 0~ 200© / 0~ 2000©
Earth Voltage [ 50, 60Hz] : 0~ 200V AC
Accuracy Earth Resistance: ± 2% rdg± 0.1© ( 20© range)
| ± 2% rdg± 3dgt ( 200© / 2000© range)
Earth Voltage: ± 1% rdg± 4dgt
Overload Protection Earth Resistance: 280V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage: 300V AC for 1 minute
Safety Standard IEC 61010-1 CAT.III 300V Pollution Degree 2, IEC 61557
Applicable Standards IEC 60529 IP54
Withstand Voltage 3700V AC for 1 minute
Power Source R6P ( AA) ( 1.5V) × 6
Dimensions 105( L) × 158( W) × 70( D) mm
Weight 550g approx.
Accessories 7095 ( Test Leads) × 1set ( red-20m, yellow-10m, green-5m)
8032 ( Auxiliary earth spikes) × 1set
7127 ( Simplified measurement probe) × 1set
R6P ( AA) × 6
Neck strap