COLUMN CHILLER MODEL CO50 TORREY PINES SCIENTIFIC
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalAmerika Serikat

Keterangan

COLUMN CHILLER
Programmable single column unit with column temperature range from 4.0 °C to 100.0 °C MODEL CO50 TORREY PINES SCIENTIFIC

Model CO50 Programmable single column unit with column temperature range from 4.0 °C to 100.0 °C

Model CO50 Features:
Full programmability. Stores 5 programs of up to 10 steps each in memory for instant recall and use. Each program can be made to repeat automatically from 1 to 99 times.
Temperature range from 4.0ºC to 100.0º. Can control at or near room temperature regardless of changes in room temperature.
Readable and settable to 0.1ºC.
Accuracy to ±0.2ºC
Built-in stable temperature light which illuminates when set temperature is reached and is stable.
Resettable, built-in column injection counter. Counts to 1000 injections.
Chamber size 15â (38.1cm) long x 1.5â (3.8cm) wide x 1.5â (3.8cm) deep. Has clamps that hold ¼â diameter or â diameter columns up to 30cm long with room for fittings.
Chamber milled from one piece of aluminum. The floor is sloped to the right where a ¼â OD tube exits the chamber for collecting any spills.
Easy top cover access to columns and fittings.
Energy efficient Peltier chilling and heating. No CFCâs or other refrigerants.
PID temperature control of chamber using accurate platinum RTD temperature sensor.
30-day count down timer with alarm and user settable Auto-Off that turns the heater/chiller off after the timer counts to zero.
RS232 I/O port for control by computer or chromatograph, or for data collection.
Electronic calibration held in memory without the need for batteries.
12-month warranty
UL, CSA and CE compliant

Product Description:

C050 Chilling/Heating HPLC Column Oven is completely solid state. The only moving parts in the unit are the coolings fans. This makes the design of the C050 truly reliable. Being Peltier based, it has no compressors of CFC's to worry about. This design makes the unit very energy efficient using only 120 watts of power maximum. That is less than many light bulbs.

The display is a back-lit, two-line alphanumeric type with 16 characters per line. It displays target and actual temperature, count-down timer and injection counter if used. It also displays program number and step while running a program. The display reads to 0.1ºC and displays the timer from 30 days to 1 second. When the timer counts down to zero and audible alarm will sound for I minute and the timer will start to count up showing the user how much time has expired since the timer counted to zero.

To set a temperature touch the UP or DOWN arrows until the display shows the target temperature required. The unit will now heat or chill automatically to reach and hold that target while displaying the actual chamber temperature at all times. When the target temperature stabilizes, the Stable Temp light will illuminate and stay lit as long as temperature is stable.

The chamber is machined from a solid piece of aluminum for excellent conductivity and integrity and is anodized to protect the surface. It is 15â (38.1cm) long by 1.5â (3.81cm) deep and wide and can accommodate most commonly used columns and fittings. There are slots in both ends for entering and exiting tubing. The chamber has a sloping floor that tilts toward the drain on the right end of the chamber. The drain tube is 1/4â OD by 1/8â ID for matching readily available tubing. There are three column spring clamps in the chamber for ¼â and 3/8â diameter columns. Column simply snap into place and are held snuggly.

The CO50 chamber is insulated with chemically resistant silicon rubber. The case construction is ABS plastic and sheet steel painted with chemically resistant epoxy paint. The cover is machined from block polycarbonate to resist heat and chemicals.

The unit comes complete with a universal power supply that takes AC line inputs from 100 to 260VAC, 50/60Hz and converts that to 12 volts DC for operating the unit. Also included are a three-wire, grounded AC line cord for the country of use, column counter cable, and userâs manual.

Product Specification:
Temperature: Range 4.0 °C to 100.0 °C
Readability 0.1 °C
Accuracy ±0.2 °C
Stability ±0.2 °C
Sensor Type Platinum RTD
Controller Type PID
Uniformity ±0.5 °C

Timer: Range 30 days
Readability 1 second
Audible Alarm Yes
Auto-Off Yes

Electrical: Heater/Chiller Peltier, 100 watts
Power Consumption 120 Watts AC
On/Off Switched Yes
Electrical Universal Bench Top power supply. 260 VAC, 50/60 H2 and converts that to 12VDC for the unit.

Chamber Dimensions:
Length 15.0 inches, (38.1 cm)
Width 1.0 inch, (2.54 cm)
Depth 1.5 inches, (3.8 cm)

Overall Chassis:
Height 6.25 inches (15.9 cm)
Width 7.90 inches (20.1 cm)
Length 7.90 inches (42.5 cm)
Weight unpacked 14.5 pounds (6.6 kg)