Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotrade.co.id/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

KYORITSU 8035[23 Mar. 2009, 4:03:57]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalJepang

Keterangan

• New technology permits safe testing, without the need of direct contact between probes and live wires.
• The insulated crocodile clips can clip insulated cables from Æ2.4 to 30mm.
• Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
• The instrument can be fixed to a metal panel via the magnet on the back side.
• Wide measuring range for 3 phase installations from 70V to 1000V AC.
• Super brightness function permits clear LED's indication also in sunshine.
• Complies with IEC 61010-1 CAT.IV 600V and CAT.III 1000V.

Functions : Phase rotation (Clockwise or Counter Clockwise),
Presence of open phase
Detection method : Electrostatic induction
Measuring voltage range : From 70 to 1000V AC phase to phase (sine wave, continuous input)
Clamp diameter range : From Æ2.4 to 30mm insulated cables
Measuring frequency range : 45 to 66Hz
Phase rotation : Clockwise:
Green arrow LEDs "rotate" in clockwise, Green symbol "CW" lits, Intermittent buzzer

Counter Clockwise:
Red arrow LEDs "rotate" in counter clockwise, Red symbol "CCW" lits, continuous buzzer
Visual indication : Via LEDs with Super brightness function
Battery voltage warning : Power LED blinks if battery voltage is too low.
Operating conditions : Temperature/Humidity Ranges -10 to 50ºC, 80% (no condensation)
Storage conditions : Temperature/Humidity Ranges -20 to 60ºC, 80% (no condensation)
Applicable standards : IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree2,
IEC 61326-1, IEC 61557-1, -7
Power supply : Alkaline battery (LR6) ×4
* Continuous use: Approx. 100 hours (Auto power off in about 10 min.)
Dimensions : 112(L) × 61(W) × 36(D) mm
Weight : Approx. 380g
Test leads : Double insulated cables, length approx. 70cm
Colours code : L1(U): RedL2(V): WhiteL3(W): Blue
Accessories included : 9096 (Carrying case), Alkaline battery (LR6) × 4, Instruction manual