Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotrade.co.id/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

KYORITSU 6300
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalJepang

Keterangan

• All necessary Power Measurements : V, A, W, VA, Var, Wh, VAh, Varh, cos¸, In, Hz.
• Recording function with "integration time" selectable from 1 second to 1 hour.
• Internal non volatile Memory for non-stop recording up to 10 days.
• Accepts Removable Compact Flash Memory up to 128MB for non-stop recording up to 5 years.
• Supplied with interface software for downloading data to PC via USB.
• Four wiring con.gurations : 3 Phase 4 Wires, 3 Phase 3 Wires, single Phase 3 Wire and 2 Wires.
• Wide screen with back light Multi-Display system for simultaneous measurements.
• Double power supply system : from AC Line and from Alkaline battery with approx. 7 hours of battery life.
• Demand function for Energy-Saving measurements.
• Designed to Safety Standard IEC 61010-1 CAT.III 600V.
12 kinds of power measurements
Voltage (RMS), Current (RMS), active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor (cos ¸), frequency , demand measurement, current flowing on the neutral line (Only on3 phase 4 wire measurement)

Regenerative electric power can be measured
Detection of consumption power and regenerative electric power Regenerative electric power: This is the electric power which is generated by private power generator, and is supplied to electric power company.

The electric power and the power factor for each phase can be confirmed
Monitoring of operation for each phase.

Recording internal can be set between 1 second and 1 hour
1/2/5/10/15/20/30 second/seconds 1/2/5/10/15/20/30 minute/minutes 1 hour

Demand measurement
Buzzer sounding and backlight blinking give warning not to exceed the pre-setting demand target value.

Double power supply system AC line and Alkaline size AA battery LR6 : 6 pcs.
Continuous 7 hours can be measured by using batteries

Display 3 different data simultaneously on large screen.

4 types wiring system
1 phase - 2 wire (1ch) (2ch), (3ch)
1 phase - 3 wire
3 phase - 3 wire
3 phase - 4 wire

Direct communication with PC by USB connection

The interface for compact flash card (CF card) is equipped.
An external memory up to 1GB or less can be used.

Demand Function

Measurements and parameters : Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, *Reactive energy, Power factor
(cos ¸), Neutral current, Frequency meter.
Wiring connections : 1P 2W, 3P 4W, 3P 3W, 1P 3W
Voltage :
Ranges [RMS] : 150 / 300 / 600V (CF: 2.5 or less)
Allowable input : 10~110% of each range
Display ranges : 5~120% of each range
Accuracy : ±0.3%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current :
Ranges [RMS] : 8128 ( 50A type ) : 5 / 10 / 20 / 50A
8127 ( 100A type ) : 10 / 20 / 50 / 100A
8126 ( 200A type ) : 20 / 50 / 100 / 200A
8125 ( 500A type ) : 50 / 100 / 200 / 500A
8124 ( 1000A type ) : 100 / 200 / 500 / 1000A
8129 ( 3000A type ) : 1000 / 3000A
(CF:3.0 or less. 90% or less of each range)
Allowable input : 10~110% of each range
Display ranges : 1~120% of each range
Accuracy : ±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(sine wave, 45~65Hz)
Activa power accuracy : ±0.5%rdg±0.2%f.s. + Accuracy of Clamp sensor
(Power factor 1, Sine wave, 45~65Hz)
Frequency meter range : 40~70Hz
Frequency meter accuracy : ±3dgt
Effect of power factor : Active power : ±1.0% rdg cos ¸=±0.5 (PF=1)
Integration time for recording function : 1/2/5/10/15/20/30 Seconds 1/2/5/10/15/20/30/60 Minutes
Display update period : 1 second
Operating temperature and humidity ranges : 0~+50ºC, less than 85% RH (without condensation)
Storage temperature and humidity ranges : -20~+60ºC, less than 85% RH (without condensation)
Over load protection :' Voltage : 720V AC rms
Current : 600A AC rms (with Clamp sensor MODEL 8125)
PC communication Interface : USB
CF card Interface : Compact flash card (Standard type 32/64/128/256/512MB/1GB)
Safety standard : IEC 61010-1 CAT.III 600V
Power supply : AC Line : 100~240V±10% (50/60Hz)
DC Battery 9V : LR6×6(Battery life approx. 7h)
Power consumption : 10VA (MAX)
Dimension : 175(L)×120(W)×65(D) mm
Weight : Approx. 800g (including batteries)
Accessories : 7141 (Test Lead : 4pcs),
7148 (USB Cable),
7170 (Power cord),
8307 (Compact Flash card 128MB),
8319 (CF Card reader),
9125 (Carrying bag),
PC Software, Batteries × 6, Quick manual
Optional accessories : 8124,8125,8126,8127,8128 (Load Current Clamp Sensor).
8129 (Flexible Clamp Sensor).
7198 (Small clips adaptor).
8312 (Power supply adaptor)
8322 (Compact flash card 256MB)
8323 (Compact flash card 1GB)
9132 (Carrying case with magnet)
Wide range of clamp sensor up to 1000A on request.

* PC OUTPUT only
* Please refer to here for the CF cards which checked.