Selamat Datang di Indotrade.co.id
Masuk | Daftar
Anggota Prioritas Prioritas Indotrade Tahun ke-13
ANDALAN INSTRUMENT GROUPANDALAN INSTRUMENT GROUP
http://indotrade.co.id/aps_weatherstation/
\"JENCO INSTRUMENT - JEKEN Ultrasonic Cleaner - E_INSTRUMENT - ASSEMBLAD Gas Analyzer - KOEHLER - MITECH Ultrasonic thickness - DAVIS Weather Station - EUTECH - SOCOREX Liquid Handling - MEMMERT - BLUE GIZMO - HACH - OHAUS Balance - VITLAB - DURAN - KETT
Informasi Kontak
Nama:

Tn. Edy Girsang/ maria [Pemasaran]

E-mail:
Situs Web:

Pesan Instan:

Windows Live: http://indonetwork.co.id/46NDMyOTQ4OjE-kxmx-zMTQwMDI4NTI.html?op=sms http://indonetwork.co.id/46NDMyOTQ4OjE-kxmx-zMTQwMDI4NTI.html?op=sms
Y!: edy_girsangta 
Nomor Telpon:

Nomor telpon Tn. Edy Girsang/ maria di BEKASI UTARA

Nomor Ponsel:

Nomor ponsel Tn. Edy Girsang/ maria di BEKASI UTARA

Nomor Faks:

Nomor faks Tn. Edy Girsang/ maria di BEKASI UTARA

Alamat:

Jl. Muchtar Tabrani , Bintang Metropol Blok A7 No16
BEKASI UTARA 17122, Jawa Barat
Indonesia

Alamat Tervalidasi

www.andalaninstrument.com
Rata-rata Tinjauan Pemakai
Tidak ada ulasan untuk perusahaan ini Menulis tinjauan

Unduhan (10)
Brosur Met One Auto....brosur Met One Data....Brosur Gray wolf multy....Brosur Chiyoda Pipet....3gtrack GPRS Data....3gtrack GPRS Modem3gtrack GPS Tracker GS....AIRMAR Ultar Sonic....Lihat semuanya

Jual

Staplex® TSP and TSP-2 Series Total Suspended Particulate ( TSP)[13 Jun. 2011, 13:44:47]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Negara AsalAmerika Serikat
Staplex® TSP and TSP-2 Series Total Suspended Particulate ( TSP)

- Air Sampler System
- US EPA designated method for sampling total airborne particulates

Specifications

Model TSP-1 Total Suspended Particulate Air Sampling System, 110-125VAC

Model TSP-2 Total Suspended Particulate Air Sampling System, 220-230 VAC

( specify accessory configuration when ordering)

Staplex® Model TSP-1 and TSP-2 Total Suspended Particulate High Volume Air Sampling System is designed for fast, accurate collection of suspended particulates in accordance to U.S. EPA specifications.

These complete air sampling systems, available with various modular accessories, are designed to meet the EPA requirements for sampling airborne particulates at a known flow rate for a determined amount of time, allowing for proper calculation of airborne particulate concentrations.

Basic System

The basic Staplex® TSP Air Sampling System includes Staplex® High Volume Air Sampler ( Model TFIA 110-120 VAC or Model TFIA-2 220-230 VAC) with vertical mount flowmeter; SH810 8" x10" Filter Holder Assembly and SAM Aluminum Outdoor Shelter.

Filters - Staplex® Type TFAGF810 8" x10" Glass Fiber Filters recommended for Total Suspended Particulate Air Sampling

Staplex® TSP and TSP-2 Series Total Suspended Particulate ( TSP)

Air Sampler System ( Click to open pdf literature file)
US EPA designated method for sampling total airborne particulates

Specifications

Model TSP-1 Total Suspended Particulate Air Sampling System, 110-125VAC

Model TSP-2 Total Suspended Particulate Air Sampling System, 220-230 VAC

( specify accessory configuration when ordering)

Staplex® Model TSP-1 and TSP-2 Total Suspended Particulate High Volume Air Sampling System is designed for fast, accurate collection of suspended particulates in accordance to U.S. EPA specifications.

These complete air sampling systems, available with various modular accessories, are designed to meet the EPA requirements for sampling airborne particulates at a known flow rate for a determined amount of time, allowing for proper calculation of airborne particulate concentrations.

Basic System

The basic Staplex® TSP Air Sampling System includes Staplex® High Volume Air Sampler ( Model TFIA 110-120 VAC or Model TFIA-2 220-230 VAC) with vertical mount flowmeter; SH810 8" x10" Filter Holder Assembly and SAM Aluminum Outdoor Shelter.

Filters - Staplex® Type TFAGF810 8" x10" Glass Fiber Filters recommended for Total Suspended Particulate Air Sampling

Accessory Items

Timers

DTM-1 and DTM-2 Digital 7-Day Timer Turns Air Sampler " ON" and " OFF" at set times, 24 hours a day, 7 days a week. All functions are digital and quartz crystal controlled; includes digital clock with 1/ 4-in. LED display and 7.2 VDC rechargeable stand-by battery; intuitive programming format. Specify Model DTM-1 for 120 VAC, 60 Hz; Model DTM-2 for 230 VAC ( specify 50 or 60 Hz when ordering) .

MT-1 and MT-2 Mechanical 7 Day Timer Turns Air Sampler " ON" and " OFF" at set times ± 15 minutes, 24 hours a day, 7 days a week. Specify Model MLT-1 for 120 VAC, 60 Hz; Model MLT-2 for 230 VAC, 50 Hz

DTM-4CDT Digital Countdown Timer Turns Air Sampler " OFF" after preset times. Features LCD display and thumb-wheel setting dials. ( range from 99, 999 hours to 1 second) . Size: 3" x 4-1/ 4" x 5" ( 7.6 cm x 10.8 cm x 12.7 cm) ; Weight: 1.75 lbs. ( 0.8 kg) . Usable for 110-125 VAC, 220-240 VAC and 24 VDC.

ETI-1 and ETI-2 Elapsed Time Indicator Shows sampler run time in hours and hundreths ( 99, 999.99 hours) . Standard models are non-resettable mechanical models. Specify Model ETI-1 for 120 VAC, 60 Hz.; Model ETI-2 for 220 VAC, 50 Hz. ( Re-settable model ETI-1R is also available for 120 VAC.)

Constant Flow Controllers Models FC-1 and FC-2 - Automatically maintains a constant mass flow through an High Volume Air Sampler regardless of filter loading, atmospheric conditions and line voltage. Specify Model FC-1 for 115 VAC; Model FC-2 for 230 VAC. [ requires SH810 filter holder assembly]

Models FC-1ETM and FC-2ETM include built-in non-resettable Elapsed Time Indicator.

Models FC-1MLT and FC-2MLT include built-in Mechanical 7-Day Timer and non-resettable Elapsed Time Indicator.

Flow Recorder - Models FR-1 and FR-2 - Provides a permanent record of High Volume Air Sampler performance during a 24-hour period. Specify Model FR-1 for 115 VAC; Model FR-2 for 230 VAC.

Calibration Kit - Models CKHV810 - U.S. EPA prescribed method for accurate calibration of High Volume Air Samplers. U.S. EPA recommends that High Volume Air Samplers be re-calibrated at least once per year ( or when major components such as the motor or flowmeter are changed) . Model CKHV810 can be used with 4" or 8" x 10" filter holder assemblies.

M10 Size Selective Inlets - for U.S. EPA PM10 environmental air sampling. Staplex® PM10 Size Selective Inlet is available separately as Part No. PM10-SSI for conversion of existing TSP ( Total Suspend Particulate) High Volume Air Sampling Systems to PM10 System.

4, 5 & 6 Stage High Volume Cascade Impactors - for particle size separation